Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Yes I am from India. I buy from Mouser, Element14 or local electronics distributors.
Is it possible that this problem occurs due to inability of Voltage source to supply required current or load drawing more current? or Is it a problem of MOSFET?:
Klaus, I do not mean that. In any way if I sound like if "I want you to do my job" then I am sorry. I am only asking for the part number because I am not sure how to pick the right one and there are so many of them. As someone suggested, I have also ordered NSS60600 and the power switches like...
I think in this application, I need to have Voltage, Current, On resistance and wattage rating of the component. I have only one PMOS FDD4141 that is why I have tried it. And it does have very low on resistance (10-15 mOhm) and 12A Current. What other parameter should I consider for this...
I want to build a circuit using which I can select the output power source using Arduino GPIO. I am trying this one:
In this circuit I am trying to switch a power supply to some load. Selection is between 14.8V external Power supply and 5V (Arduino's Power Supply). I want output to be...
I think you are confused with my question. I am not sending Null-terminated string. I am sending bytes 0x00 0x01 0x02 (uint8_t) with UART. And as byte will have value from (0 to 255) or (0x00 to 0xFF). It should send 0x00, which it is sending in first case i.e. sketch 1 successfully. It does not...
Hardware
Hardware: ESP-12E
Core Version: 2.3.0
Settings in IDE
Module: Generic ESP8266 Module (ESP-12E)
Flash Size: 4MB/1MB
CPU Frequency: 80Mhz
Flash Mode: qio
Flash Frequency: 80Mhz
Upload Using: SERIAL
Reset Method: nodemcu
System Setup
I am using ESP-12E, a separate power supply and...
Community will be glad that it has helped you. Please share your result / changes / suggestion here, so it will provide the reference for future. I am interested in your changes, may be it can solve many of my problem. If you have got your answer, please mark the thread as solved.
Hi Ranbeer,
If you are doing according to what you have mention, I think you are doing fine. Even if you are not getting the results then you need to check it step by step. If you are ok with that then please follow this.
I advice you to post this on ESP community forum "here" as well, so no...
In web browser if you type IP address without the port number, it will by default try asking server for the connection on the port number 80. Here in your ESP module when you try AT command :
AT+CIPSERVER=1,1234;
You are actually opening server on port number 1234.
So from web browser you need...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.