Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by DesgEng

  1. D

    M12 D-coded connector for Ethernet applications

    Hi all, Has anyone used panel mount M12 connector D-coded for Ethernet applications (10 and 100Mbps). If yes please reply ASAP. Thanks.
  2. D

    Ethernet LAN PHY termination

    Thank you very much for the information provided. Added after 5 hours 58 minutes: Hi, I've one more question related to Ethernet protection. I've a requirement of 16KV injected on M12 connector(used instead of RJ45) pins. and battery protection(Battery voltage: 16.2V to 72V). Ist a good...
  3. D

    Ethernet LAN PHY termination

    Hi, Thanks for quick reply. I was referring to CM termination resistor (75ohm with a high voltage capacitors after the Magnetics.) Please refer the attached file Page 9. Thanks
  4. D

    Ethernet LAN PHY termination

    hi, i'm working on ethernet for first time and using a industrial M12 connector instead of RJ45. I'm also using a 75ohm termination resistor along with 2KV capacitor. Wanted to know if 0.5W 75ohm resistor is sufficient and also any calculations related to termination resistor calculation is...