Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by chupos

  1. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    DG411 is available from maxim, so you can easily get them as samples. back to my problems, I've really no clue of why I'm getting all the time Connecting to MPLAB ICD 2 ICD0289: Unable to re-program ICD2 USB OS firmware. ICD0021: Unable to connect with MPLAB ICD 2 MPLAB ICD 2 Ready Got a...
  2. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    k, replaced my 18F4550, and now I'm getting Connecting to MPLAB ICD 2 ...Connected ICD0082: Failed MPLAB ICD 2 operation MPLAB ICD 2 Ready seems as if MPLAB doesn't like me :( anyone could please help me? --- after replacing the 16F877A, now it stays forever at Connecting to MPLAB ICD 2...
  3. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    thanks again for your reply, but 300009 is already 1100 0000 :( my config bits: **broken link removed**
  4. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    thanks for your answer andy :) added the pull-up and pull-down resistors and changed the 10uF to a 1uF capacitor on Vusb, but still no luck. My FOSC,CLKDIV config value is: 0000 1111 0010 0100. Is that correct? I'm kinda lost with the value table of the datasheet :/
  5. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    no PCB at all, it's mounted on a breadboard, and without external pull-up, the internal pull-up is working perfectly fine, if it wasn't, windows wouldn't detect the device correctly. PS: I'm using a 20MHz xtal also for the 18F4550, maybe that's a problem and it should be 24MHz? But then I...
  6. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    ok... now I'm getting always Connecting to MPLAB ICD 2 ICD0289: Unable to re-program ICD2 USB OS firmware. ICD0021: Unable to connect with MPLAB ICD 2 MPLAB ICD 2 Ready and I'm not getting anymore the connect/disconnect sound while in MPLAB, (only when I really connect the device). Could...
  7. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    First I'd like to thank everyone who has contributed to this project. But I got a small (or huge) problem. I've built it now on a breadboard, windows detects the 4550 correctly, installs the microchip drivers, but when I tell MPLAB to connect, I hear the windows sound of "usb device...
  8. C

    looking for free graphic library in MFC

    you could also use the free GD library, but it doesn't provide any real advantage over GDI+.
  9. C

    Problem with detecting DS1075 on a 1-wire network

    Re: DS1075 yes it is. programmable via 1-wire.
  10. C

    Problem with detecting DS1075 on a 1-wire network

    Re: DS1075 already tried with 5 different chips.
  11. C

    Problem with detecting DS1075 on a 1-wire network

    hi, I'm having some trouble with the DS1075. I'm using a DS2490 to connect a 1-wire network to the PC, and it works with everything I tested, for example DS1990. but for some reason, it won't detect the DS1075 on the 1-wire network. the DS-1075 is connected to the GND and the 1-wire, using a...
  12. C

    Looking for schematic for ICD2

    icd2 target 3v one is for PIC 16F877 and the other one is for 16F877A
  13. C

    6L SOT23 to DIP Adapter

    there are some other companies selling those adapters, but they won't be much cheaper. Point probably would be, either to solder wires to each pin ( I did that when prototipying with the DS2490 ) or to make an adapter PCB, and solder with a lot of time, and being really careful the SMT-chip to...
  14. C

    PIC programmer schematic

    schema ic prog PPwin for example? :) **broken link removed** hope it helps you :)
  15. C

    Help me design a weight detector for a water filling system

    Re: Weight Detector I would also suggest using a load cell, as they are pretty easy to use and calibrate, and are really accurate. If you need more info on load cells, I can provide some, as I work with them pretty often :) The suggestion of using a flow meter, is, in my opinion, not very...