Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Thanks again for appropriate and useful information! Now, I understand, for reliable energizing the relay, we shall give minimum rated voltage independent of COLD or pre-energised state over it's operating temperature range.
Thanks!
Thanks! I understand "There's a factor of e.g. 2 or 2.5 between engage and release voltage by nature of the magnetical circuit.".
I would like to clarify about my question by giving example - If a relay is not energised for a long time (i.e. it is in COLD state). Suppose, now we energise it...
Thanks again for appropriate information!
I have one datasheet as a reference which states that in cold state relay, over entire temperature range Operate voltage varies approximately +/- 20% of the its nominal operate voltage at 20 degree Celsius. However in pre-enegised state, operate voltage...
Thanks for appropriate information! Sorry, I forget to mention the DC coils. I interprete from the graph - Over entire temperature range Operate voltage varies approximately +/- 15% of the its nominal operate voltage at 20 degree Celsius. Over entire temperature range Release voltage varies...
Then it looks LM317 is good solution for your circuit! I think, DC-DC may not give more benifit other than size ..Also, you must be aware of DC-DC pros and cons..It does not seem to be worth for your circuit...
Happy New Year to All!!!
I guess,
- high efficiency dc-dc conveter will improve power efficiency and not brightness of LEDs . It will have little or no impact on brightness of LEDs as illumination mainly depends on current flowing through it. If current is switched then only illumination will be affected. There is no...
Thanks for the information!
I would like to know what would be the impact of temperature. As you said, coil voltage needs to be maintained. Does it mean - relay would not be able to operate at the coil voltage at higher temperature; which used to operate at the same voltage at nominal...