Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by brandon.tarr@restek.com

  1. B

    Open circuit ground multiplexing?

    That's correct. The air gap essentially acts like a really big resistor while the electrospray is happening. So, the low side circuitry will never see 4kV. If the air gap gets too small and turns into a spark gap, the plasma created by the arc will act as a much lower value resistor. When...
  2. B

    Open circuit ground multiplexing?

    For clarification, I already have a current measuring system, so I would rather not design one from scratch if it isn't necessary. I am specifically asking about the identification of multiplexer transistor architectures (if any) that are capable of switching ground to a no load, high Z or...
  3. B

    Open circuit ground multiplexing?

    The range of the pico-ammeter is pico (well technically I guess fempto since the resolution on the lowest scale is 100 fA) through milli, so yes, I'm measuring nA with a "pico-ammeter". Now, back to our regularly scheduled program...
  4. B

    Open circuit ground multiplexing?

    Hi all. I am experimenting with electrospray ionization. The setup has a 4kV power supply connected to an electrode that is separated from a return lug (or ground plate) via an air gap, followed by an inline pico-ammeter and finally ground. The way this works is that a small drop of solvent...