Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by bkelciov

  1. B

    APC UPS SURT10000RMXLi defective

    I have a defective UPS SURT10000RMXLi. Some components exploded and some just not working. I have 2 optocouplers A3131 defective and I don't know if there is replacement for them and I don't have datasheet for them. I found 2 possible replacements HCNW3120 and ACNW3130 but I don't know if one of...
  2. B

    Asus K54C BIOS dump needed

    Hello, After updating BIOS at notebook Asus K54C, it wont POST. Black screen, no HDD activity. I have read the content of the flash ( W25Q32BVSIG ) and tried to write the .rom file from the ASUS site. Failed to do that. I have bought 2 pcs W25Q32BVSIG. I have successfully write the flash but...
  3. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard APC UPS does not work with straight cable. APC use proprietary cable: 940-0024D
  4. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard Maybe you have another program that is using COM port. The programm "PowerChute" from APC is doing that. Try to connect the UPS on a fresh installed Windows XP. I don't remember what Windows I did use. The cable must be 1 to 1 pin ( straight ) !!!
  5. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard Yes, the serial cable must be straight.
  6. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard You can try. I realy don't know if it's working.
  7. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard The cable must be straight. Wait few days. Maybe somebody from masterguard will answer you.
  8. B

    ESR meter project from Nuova Elettronica

    We can't pinpoint the problem. You have to do that. We only can guide you. Check the circuit board and the components. Look for shortcuts or discontinued trails, check for +5V and -5V ( in fact is only -4.2V ). Change LM393 and CD4066, swich DA1 with DA2. Make sure to write correct hex for your...
  9. B

    ESR meter project from Nuova Elettronica

    first SET to zero, then calibrate for 1 ohm then calibrate for 10 ohm. But first SET to Zero.
  10. B

    ESR meter project from Nuova Elettronica

    How did you calibrate ? Try to replace the TL431.
  11. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard The password / key to use the PPSet V2.0 is written below the file. Read previous post above.
  12. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard So, before changing battery the UPS worked in normal mode ?
  13. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard Try to use this programm with this key: 2680-331941-11410 If it's not working with this key you have to request a new programm and a new key from: **broken link removed** Good luck.
  14. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard Problem solved. I have received from "Masterguard.de" the software for reseting battery age. It's called "PPSet V2.0". Thank you for your advices.
  15. B

    [SOLVED] Reset UPS Masterguard

    Re: Help reset UPS Masterguard Nope, the load trick did not work. I have tried with 800W load. In the MopUPS the battery is reported as 95% charged. The battery were new and charged before installing. Still no luck.