View RSS Feed

Anil Pandey : Electronics Design and Simulations

Time Domain Reflectometry (TDR) Analysis of Transmission Lines

Rate this Entry
Click image for larger version. 

Name:	tdr0.jpg 
Views:	1573 
Size:	110.8 KB 
ID:	136238
Time Domain Reflectometry is the analysis of conductor lines (interconnects)by sending a pulsed signal into the conductor and then examining the reflection of that pulse. A TDR transmits a short rise time pulse along the conductor. If the conductor is of a uniform impedance and is properly terminated, the entire transmitted pulse will be absorbed in the far-end termination and no signal will be reflected toward the TDR. Any impedance discontinuities will cause some of the incident signal to be sent back towards the source. By examining the polarity, amplitude, frequencies and other electrical signatures of all reflections; tampering or interconnect discontinuity may be precisely located

Time Domain Reflectometry is the analysis of conductor lines (interconnects) by sending a pulsed signal into the conductor and then examining the reflection of that pulse. A TDR transmits a short rise time pulse along the conductor. If the conductor is of a uniform impedance and is properly terminated, the entire transmitted pulse will be absorbed in the far-end termination and no signal will be reflected toward the TDR. Any impedance discontinuities will cause some of the incident signal to be sent back towards the source.
By examining the polarity, amplitude, frequencies and other electrical signatures of all reflections; tampering or interconnect discontinuity may be precisely located.

Click image for larger version. 

Name:	tdr1.jpg 
Views:	235 
Size:	54.3 KB 
ID:	136230

TDR: Working Principle

With TDR, step pulse voltage is input into the transmission circuit and the voltage reflected in the transmission circuit is measured over time. The characteristic impedance of the circuit board is then calculated from the voltage drop in the reflected voltage.

Click image for larger version. 

Name:	tdr2.jpg 
Views:	459 
Size:	128.6 KB 
ID:	136231

TDR Simulation Result of Transmission Line in Smart phone from USB to Chip

TDR Pulse (step waveform) is very important. Rise Time value specifies the rise time of incident TDR pulse. The resolution of a TDR measurement system is directly related to the rise/fall time of the incident pulse. Rise time is specified with either a 10%-90% or a 20%-80% definition.

Click image for larger version. 

Name:	tdr3.jpg 
Views:	240 
Size:	105.8 KB 
ID:	136232

For example, consider a 20* timestep rise time for a 10%-90% definition, there will be 20 time steps between the time where the waveform has a value of 0.1 to the time it reaches a value of 0.9.

Click image for larger version. 

Name:	tdr4.jpg 
Views:	254 
Size:	151.4 KB 
ID:	136233

Initial glitch on TDR response Since the instantaneous TDR response is directly calculated from V/I, it reveals the initial glitch on TDR response. It is due to the zero current flowing through at the time = 0