Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Question in CAN (Controller Area Network)

Status
Not open for further replies.

kishorekumar_ms

Member level 5
Joined
Nov 12, 2006
Messages
84
Helped
2
Reputation
4
Reaction score
2
Trophy points
1,288
Activity points
1,815
pca82c251

hi frns,

Please tell me
1. what happens when we apply +ve voltage to CANH (CAN High Signal) and Ground to CANL (CAN low signal) ?

2.What happens if we ground both CANH and CANL ?

3.Can u give clear idea or clear diagram about CANH and CANL to represent logic '0' and logic '1'?

Thanks & Regards,
M.S. Kishore Kumar.
 

The PCA82c251 is a CAN transceiver. Let's take a look in the data sheet for your three questions.
**broken link removed**

1. page 5 says - no problem. Voltage V6 and V7 can be between -37V and +35V.
The truth table (page 4, table 1) says thats a logical 0.

2. nothing because CAN is a differential signal transmission system, means no difference -> no signal.

3. take a look at truth table (page 4, table 1)


Regards
Gomez
 