Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

this error means what when computing using CST MWS 5.0 ?

Status
Not open for further replies.

sanders

Member level 3
Joined
May 21, 2006
Messages
57
Helped
1
Reputation
2
Reaction score
1
Trophy points
1,288
Activity points
1,787
I encounted this error today: The calculation seems to be unstable! Consider reducing the value for the stablity factor in the solver specials options or reduing the PBA fill limit in the automesh properties. This error means what? I guess that is because i had adopted an unfit template, i should adopt another template or just not choose template at the beginning. Any help will be appreciated!

Can i delete the template if i find it is unfit or i can only substitute it with another one ?

Best regards!
 

this error means that the FDTD solver encoutered some problems in the stability (cannot solve the problem). So go to transient solver, click specials then go to the solver tab you will find "stability factor = 1" change the 1 to 0.5 and try to run the simulation (this usually works for me) you may need to decrease it further in some cases
 

Thank you! Then how to understand the value of the stability factor, what had happened when the simulation is unstable?

Best regards!
 

Hi sanders

It also happens if there is resonance in your frequency band or return loss close to zero Consider to reduce the frequency Band to exclude these frequencies.

pl
 

Hi,asel_48, i have reduced stability factor from 1 to 0.5 and 0.3, but the problem still exists.Thank you , plasma,i will try to reduce the frequency band.

Best regards!

Added after 3 hours 13 minutes:

Now i encount a new error: Maximum number of pulse widths simulated,solver stopped.Please note that the steady state energy criterion has not been reached.what does it means? Thank you !

Best regards!
 
Because you have unstable project its take longer time for the pulse to decrees so give it more time change 20 pulse to 50 in solver menu
 

    sanders

    Points: 2
    Helpful Answer Positive Rating
Hi,plasma, i have another question to ask, i was doubted by "error in X-plane at index (x/y/z) :6,29,6 [error in correction type B]", this error occured continuously when the simulation was on, then what does it mean? Thank you in advance!

Best regards!
 

Look at boundary try to set it few mm away or try to increase the mesh in this point

pl
 

You should enable PBA Accelarator mode... and the error gets fixed.

But I think that this option is not available in MWS5, but is available in higher versions.
 

By improving the mesh density your structure will be more stable .

look at previews question " some question about CST MWS ".

8_1158823475.JPG
 

    sanders

    Points: 2
    Helpful Answer Positive Rating
To my opinion, The two errors you have described indicate a problem caused by the mesh settings you are using.

a. I recommend that you set the Stabilty and Mesh filling ratio to their defaults and try meshing the model differently - try using fix-points around critical areas like ports or edges.

b.Simplify the model. For example, If you are using a waveguide port, try replacing it with discrete port and see if the problem recurs.

Good luck,
P.
 

as u said i got answer after reducing it ?
but whether it ll affect result accuracy ?
 

Status
Not open for further replies.

Similar threads

Part and Inventory Search

Welcome to EDABoard.com

Sponsor

Back
Top