Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

How to use an analog umeter to read dB ?

Status
Not open for further replies.

pierino

Newbie level 2
Joined
Aug 7, 2005
Messages
2
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,301
dB meter

Hi
can someone tell me how to use an analog umeter to read dB - I am sure it can be done , maybe w/ some opamps or some passive components...!?
Any schematic(s) would be nice
THANKS
- Pierino
 

dB meter

An analog VU meter is simply an AC voltmeter with a dB scale painted on it.
Do you need something fancier than that?
Example: **broken link removed**
 

    pierino

    Points: 2
    Helpful Answer Positive Rating
Re: dB meter

Take a look at the Linear IC by National Semiconductor.
The series LM3914-LM3916.

MAKeller
 

    pierino

    Points: 2
    Helpful Answer Positive Rating
dB meter

check this

**broken link removed**
 

    pierino

    Points: 2
    Helpful Answer Positive Rating
Re: dB meter

echo47 said:
An analog VU meter is simply an AC voltmeter with a dB scale painted on it.
Do you need something fancier than that?
Example: h**p://www.sifam.com/vuppm.lasso
Thank you for your reply
What I want to make is to be able to read dB on a microvolt (or mV) meter . I will then make a new scale for the meter, but the point is to interface somehow the voltmeter to read dB. Maybe I need a log opamp amplifier .. or something similar !?
Thanks
 

dB meter

You can convert your AC signal to DC and then feed it into a logarithmic converter circuit. Try searching National Semiconductor web site for application notes containing keywords such as log, logarithmic, converter, generator, amplifier.
**broken link removed**

Here are a few examples:
**broken link removed**
**broken link removed**
 

Re: dB meter

Here are some suggestions if your intention is to construct a true "VU" meter:
~
The meter must repond to average, not peak.
~
Ballistics are important. The meter must have a response time of about 300 milliseconds.
~
VU meters are not necessarily linear in db, but if this is what you want, you must use some kind of Log converter, as Echo47 suggests.
~
Regards,
Kral
 