Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Help me analyze tmax error log

Status
Not open for further replies.

akrlot

Member level 3
Joined
Jan 14, 2005
Messages
55
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,286
Activity points
450
please how could i correct this error here's a part of the log :


------------------------------------------------------------------------------
Begin simulating test protocol procedures...
Warning: Rule S30 (unstable RAM during test procedure operation) was violated 1 times.
Test protocol simulation completed, CPU time=0.00 sec.
------------------------------------------------------------------------------
Begin scan chain operation checking...
Chain c0 successfully traced with 42 scan_cells.
Warning: Rule S19 (nonscan cell disturb) was violated 8 times.
Scan chain operation checking completed, CPU time=0.00 sec.
------------------------------------------------------------------------------
Begin clock rules checking...
Clock rules checking completed, CPU time=0.00 sec.
------------------------------------------------------------------------------
Begin nonscan rules checking...
RAM summary: #RAMS=1, #clock_unstable=0, #load_unstable=1, #read_only=0.
Nonscan cell summary: #DFF=0 #DLAT=0 #RAM_outs=8 tla_usage_type=none
Nonscan rules checking completed, CPU time=0.00 sec.
------------------------------------------------------------------------------
Begin DRC dependent learning...
Fast-sequential depth results: control=2(957), observe=2(392), detect=2(957), CPU time=0.01 sec
DRC dependent learning completed, CPU time=0.01 sec.
------------------------------------------------------------------------------
DRC Summary Report
------------------------------------------------------------------------------
Warning: Rule V14 (missing state) was violated 2 times.
Warning: Rule S19 (nonscan cell disturb) was violated 8 times.
Warning: Rule S30 (unstable RAM during test procedure operation) was violated 1 times.
There were 11 violations that occurred during DRC process.
Design rules checking was successful, total CPU time=0.01 sec.
------------------------------------------------------------------------------

set faults -model transition -atpg_effe -fault_cover
Warning: Unused gate deletion affects fault coverage calculation. (M245)

remove faults -all
0 faults were removed from the fault list.
add fault I1/A[0]
2 faults were added to fault list.
add fault I1/A[1]
2 faults were added to fault list.
add fault I1/A[2]
2 faults were added to fault list.
add fault I1/A[3]
2 faults were added to fault list.
add fault I1/A[4]
2 faults were added to fault list.
add fault I1/A[5]
2 faults were added to fault list.
add fault I1/A[6]
2 faults were added to fault list.
add fault I1/A[7]
2 faults were added to fault list.


add fault I1/D[0]
2 faults were added to fault list.
add fault I1/D[1]
2 faults were added to fault list.
add fault I1/D[2]
2 faults were added to fault list.
add fault I1/D[3]
2 faults were added to fault list.
add fault I1/D[4]
2 faults were added to fault list.
add fault I1/D[5]
2 faults were added to fault list.
add fault I1/D[6]
2 faults were added to fault list.
add fault I1/D[7]
2 faults were added to fault list.
run atpg
##############################

ERROR HERE
##############################
Error: There are no active faults in the fault list. (M114)

Uncollapsed Transition Fault Summary Report
-----------------------------------------------
fault class code #faults
------------------------------ ---- ---------
Detected DT 0
Possibly detected PT 0
Undetectable UD 0
ATPG untestable AU 32
Not detected ND 0
-----------------------------------------------
total faults 32
test coverage 0.00%
fault coverage 0.00%
ATPG effectiveness 100.00%
-----------------------------------------------
Pattern Summary Report
-----------------------------------------------
#internal patterns 0
-----------------------------------------------
 

atpg rule s30

Search for M114 in tetramanx manual , you will find justification
 

    akrlot

    Points: 2
    Helpful Answer Positive Rating
nonscan cell disturb

hi,
The log said thost 32 faults is untestable, maybe you need check why this situation.
 

    akrlot

    Points: 2
    Helpful Answer Positive Rating