Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Why mutual inductance coupling is high in microstrip line

Status
Not open for further replies.

hioyo

Advanced Member level 4
Joined
Aug 18, 2021
Messages
116
Helped
0
Reputation
0
Reaction score
2
Trophy points
18
Activity points
899
Dear Team,

I was learning about crosstalk in PCB from the High-speed signal propagation book by Howard Johnson.
It says mutual inductance coupling is high in microstrip line compared to mutual capacitive coupling.
May I know why it is like that

Regards
HAri
 

Isn't that normal ? Distributed Inductance along Line Length and Magnetic Coupling due to this reason is dominate. Capacitive Coupling occurs at fringe sides of the Line and it's ( Electrical Coupling ) relatively low compare to Magnetic Coupling.
 
  • Like
Reactions: hioyo

    hioyo

    Points: 2
    Helpful Answer Positive Rating
Thank you...
May I know what you mean by fringe sides of the Line
 

Stripline impedance is vertical to ground plane with nH/mm and pF/mm such that a w:h ratio in FR4 of 2:1 is about 50 Ohms from Zo=sqrt(L/C) There is lateral flux coupling from coplanar tracks by M being a fraction of L and C due to the thin edge crosstalk which is about 50% of the voltage for a 0.1ns risetime (near 4GHz) when the geometry for l:w:h = 10:1:1.

Directional couplers vary in design but depend on the controlled power ratio of the coupling and directional properties.

 