Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
I am simulating a 3 port circulator but i don't now what is eigenmode in hfss in hfss meno and what difference is between DM and DT and eigenmode? plz help me.
Tohoma is correct. There a lot of parameters in HFSS you need to satisfy before HFSS is happy.
1. Specify all your ports
2. Select within your model the garnets or ferrite and specify it's characters.
3. Once you've done that you should be able to select magnetic bais. If you're running HFSS alone without Maxwell, you will need to select a uniform field. If you have Maxwell, would select non uniform bias and point Maxwell.
My experience HFSS is accurate for waveguide units but bad for coaxial or drop-in circulators / Isolators.