Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

[SOLVED] area inverter and buffer

Status
Not open for further replies.

soura9

Newbie level 4
Joined
Jan 10, 2012
Messages
5
Helped
0
Reputation
0
Reaction score
0
Trophy points
1,281
Activity points
1,305
between an inverter n buffer of same drive strength which one has larger area...???
 

Buffer has larger area, because the output cascade of the buffer is the inverter (which has the same size as inverter cell with the same drive strength). So, total area of the buffer is output_inverter_area PLUS input inverter (which are smaller, than output inv).
 
thanx n can u please tell
does SPEF contains connectivity information...???
 

SPEF contains resistance, capacitance and net names. Connectivity information is taken from netlist.
 
  • Like
Reactions: soura9

    soura9

    Points: 2
    Helpful Answer Positive Rating
which is mandatory sign off check...??
lvs
DRC
LEC
????
 

means al are mandatory along with timing sign off. ryt?
 