Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by tronicman89

  1. T

    AC DC full bridge power supply

    hey Klaus Relaxe man, you are not obliged to reply me 8-)
  2. T

    function generator level shifting

    i need to shift to 3.3v 5v and 12, thank you - - - Updated - - - i need to shift to 3.3v 5v and 12v, square wave 200Mhz max fequency with controled gain, thank you
  3. T

    function generator level shifting

    hello, i have designed a function generator to be used to generate some ethernet, CAN, LIN signals so could you please help me for level shifting knowing that the level output from DAC is 1.8v
  4. T

    AC DC full bridge power supply

    im very thankful Klaus, schmitt trigger it seems that yes i will giveup keeping TX1 and i will change the design ;) thank you guys
  5. T

    AC DC full bridge power supply

    thank you klaus for your help, in fact it have a mechanical limitations (casing) so thats why i cannot use auto transformers they are more bigger than my case
  6. T

    AC DC full bridge power supply

    220V to 80V 2A transformer hello guys, in fact im working on a project and i have some mechanical limitations and i am staked to finding the smalest solution, so could you please help me to find the smallest transformer or solution to have these values 220V to 80V 2 A, thank you
  7. T

    AC DC full bridge power supply

    they are not a pcb mount also they have a big height
  8. T

    AC DC full bridge power supply

    i think planar transformer is not doable due to the primary winding number so i think im obliged to use a traditional transformer, whats the smallest solution that can i have ?
  9. T

    AC DC full bridge power supply

    thank you smijesh, yes in fact that what i realise, its very difficult to have 80v from 220v ac, in fact, my board is small to have a traditional transformer so im thinking to have planar transformer but im not sure that it exists from AC 220v to 90-80v DC they offen used for DC DC, what do you...
  10. T

    AC DC full bridge power supply

    Hi, I doubt it . The cheapest (without isolation) maybe is an autotransformer. Klaus autotransformer its isolated solution !
  11. T

    AC DC full bridge power supply

    thanks to all, so how can i get 80V 2A without transformer ?? because i saw many solution without transformer but they dont deliver enough current ?
  12. T

    AC DC full bridge power supply

    thank you, for reply i just wonder if there is a way to have AC DC without transformer to have 80v 2A then connect to DC DC converter
  13. T

    AC DC full bridge power supply

    hello guys, im designing a variable output full bridge power supply and i found an intresting design from microchip but its DC DC, so could you please help me to have AC input 230V and DC and 30V 5A as maximum output, what should i add ?..