Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Well I tried a 3 micron roughness on all surfaces of the loop and the copper loss went up by 60%. It seems pretty clear this is the root of my problem and I will probably just tweak the value until my model matches the data unless I am able to find parameters for my copper.
By the way, there...
I would never have thought that would affect me at 400MHz, but since I see a worst case of 3u roughness in the Rogers' document, and skin depth is also about 3u, it now seems very plausible. I am presently using the outer layer of an FR4 substrate (plated up to about 3mils over original 1oz...
I am making 400MHz small loops and HFSS is not predicting the same copper loss I am measuring. My hardware shows 2 to 3 times the loss that HFSS predicts. I am not solving inside the copper. It seems like the skin depth approximation should be adequate, but is there something I am not setting...