Continue to Site

Welcome to EDAboard.com

Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by Sohaibafzal

  1. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    Dear rmarkespanto, Give some details so experts can help you out...:roll:
  2. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    No one on the board knows about the Sim application ToolKit operations..... Strange...
  3. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    OK, Now i solved the restarting problem by Inserting two 7805 Voltage regulators in parallel and 100 uF capacitor as a buffer. Thank you guys (Specially FvM and ckshivaram )for all the help regarding power issues. Now i am trying to access my SIM tool kit to perform some specific operations...
  4. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    @ ckshivaram I have checked the SIM card connections, they are not shorted. @ FvM can you please suggest any other voltage regulator that can supply, 4.5V and 2A. One more thing to say, Some times its fully working, even i sent sms and make calls. But this is a very rear case. I mean if i...
  5. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    I am using 9V DC Battery to give it power. For voltage regulator, i am using LM7805, it can provide 1A of current and 5V. This supply powering up SIM300W and MAX232. When i gave it 5V, modem response was: Maximum Power limit exceed and then Normal Power Down. So i implant the DIODE after...
  6. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    Now i solved the issue with garbage values by resetting the module after power on. I new problem is faced now, when i insert the sim card in the module, it restarts after each 5 secs. I am seeing this response rapidly. FUN:1 CPIN=Ready Call Ready and then again FUN:1 CPIN=Ready Call...
  7. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    screenshot of what? Default baudrate is 9600, i checked by AT+IPC? Reset button means PWR KEY of module. When i power on the supply, and type in hyper terminal. it gives garbage value. And then i pulled down PWR KEY of module, and then it accept all the at commands. Is it a way, so i may not...
  8. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    hi, ckshivaram I have just tried these commands. But it still sending the gerbage values. And now when i reset the module using its reset pin pulled down to ground. It works fine, but when i restart the supply, it again sending the gerbage valuse. I also tried baud rate setting command as...
  9. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    Friends, Now i solve the issue, i can now write on hyperterminal screen, but this is a garbage value, different from what i was typing. Is it a problem with baud rate or connections? Thanks in advance
  10. Sohaibafzal

    [SOLVED] Bulk SMS GSM Modem Pool Using 8SIM300W Modules and ATMEGA32 with I2C Protocol

    Thanks SalmanLiaqat, Is it feasible to make 8 software UART using Bitbanging in ATMEGA32 or PIC.
  11. Sohaibafzal

    Connecting MicroController to GSM modem via RS232

    hi, all I have a problem with sim300W module, please help. When i connect my module to hyper terminal via RS232. It do nothing, i am even enable to type command from hyper terminal. Remember i am using SIM300W Module Not Modem. Pin Connections...
  12. Sohaibafzal

    [SOLVED] Bulk SMS GSM Modem Pool Using 8SIM300W Modules and ATMEGA32 with I2C Protocol

    Hi, Thanks for reply, yes multiplexing is another option, but what will happen when i receive a signal from module, i.e. Alert for SMS, Alert for call, or any other Interrupt?
  13. Sohaibafzal

    [SOLVED] Bulk SMS GSM Modem Pool Using 8SIM300W Modules and ATMEGA32 with I2C Protocol

    Hi every one, I have a plan to make a Bulk SMS Modem Pool to send Advertisment sms. I have 8 sim300W GSM modules and 1 atmega32, is it possible to make Master, slave Interface using I2C Protocol to communicate with all modules? Or i have to make 8 serial UART using BIT Banging? Thanks in Advance
  14. Sohaibafzal

    Sine Wave Inverter using PIC16F84A Microcontroller

    Hi, liteon thanks for your analysis about the Pakistanis. I think you are one of them who don't share their knowledge, and you must be ashamed of what you wrote here. ---------- Post added at 07:43 ---------- Previous post was at 07:34 ---------- Hi Tipu, Try to download the latest version...
  15. Sohaibafzal

    interface atmega with gps and GSM

    Yes you r right. Sim300 is just a GPRS/GSM modem. It has no GPS . ---------- Post added at 21:27 ---------- Previous post was at 21:17 ---------- you have to connect your MCU with sim300 using USART. For sending SMS through sim300 send these commands in sequence through UART Transmitter...