Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Re: is it correct , replacing IGBT in ups with a defferent make
I have used the semikron IGBT, and still the out put of the inverter is zero.
The DC input to the bridge is 80v, and the inverter control card is a good one , which was tested on another similar unit and found healthy.
To verify...
Re: is it correct , replacing IGBT in ups with a defferent make
The datasheets in pdf for both igbt models attatched, for finding suitablity of igbt for replacement.
is it correct , replacing IGBT in ups with a defferent make
I have a faulty 3kva online ups 230v 50hz single phase in /out , 72v DC bus.
The input rectifier section is ok, delivering 82V DC measured at inverter DC bus.Out put is 0 volt.
The IGBT used in inverter bridge is 2 nos toshiba...