Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Hi.
I assembled epe lcf meter,but I have a problem in inductance mode.
I had no chance to obtain exact inductor's value.
Trimmer VR2 is set to 0 ohm.I shorted the probes,pressed null-button and then I placed 47uH inductor.
I obtain only 44uH.If I place 330uH I obtain 311uH.
With VR2 turned on...
Hi!
Now my meter seems to work.I replaced all 1K 10K resistors with others with tolerance 1% and lf412 with tl082.Then I put 3k 30k resistors where required.I welded the probes directly on pcb,because streep line affect measure.Now I measure 0.996-1.002 for 1 ohm and 9.984-10.014 for 10 ohm...
Hi!I built a power supply pcb with two batteries,I checked voltages and these are right,then I did measure of current.I connected tester between A733 collectors(disconnected from VT2) and ground and I put R3(RC0 side) to ground.I removed cpu from socket.I measure 0A.Why?
Hi!Thanks a lot for reply.
In fact when I measure -5V without load I get -4.99V but with load I get -4.34 so this voltage are not stable.Exactly where can I measure 10mA current on circuit?Which points?
Hi to all forum's members.
I built go esr meter,dip components version.I used two lf412 in place to tl082 and a ceramic resonator ZTA 20.00MX+two ceramic capacitors of 22pF,in place to quartz resonator.For the power,to make -5V I used icl7660.I put coefficient 1.050 for 1 ohm and 0.960 for...