Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
Hi all,
i have a process under SUN SOLARIS 10 running with 5 threads.
One of them dies with a high data level processing, but it doesn't generate a core dump.
How can I get this core dump to analize the process??
Thanks.. Daniel P.
Hi all,
I have two IP channels to communicate with a GPRS server, the TCP/IP LAN and a GPRS modem.
My problem is how could my application choose between these two channels?
Thanks a lot,
dani
Hi all,
i have several disconnection on my socket TCP-IP.
i am checking the IP OSI-level and i found the ID number is not correlative for the packets sent by the remote unit.
How could i solve this problem?
How could i check the version of differents OSI levels in my SUN SOLARIS 8 ?
In one...
Re: TCP Reset connection
I have made a snoop of my socket connection, and I have checked the Identification number of the IP level.
While the ID number in the server is increased one by one, the ID number in the remote controlled station is increased in a random number, usually 300 or 400...
Re: TCP Reset connection
How could I know all the parameters of the tcp/ip implementation of both both systems (client/server?.
the server is SOLARIS 8 SO, and the client is a remote controlled station.
Re: TCP Reset connection
When the EOF character is received then the read function returns cero.
I have programmed it this way:
bytesRead = read( clisock, buffer, BUF_SIZE);
if (bytesRead > 0){
/*Se han leído datos*/
}
else {
/* Tanto si es cero o menos uno, cerramos el
socket*/
}
If i...
Re: TCP Reset connection
Thanks,
I could find the reason of this Reset message sent by the controlled station.
It is caused by the sent of the OEF character inside the telecontrol protocol.
Now, How could I solve this problem?
TCP would have to ignore this EOF character.
Thanks.
Hi all,
I have a remote controlled station behind a router connected by a TCP socket to a SCADA server.
The connection is right, but some times the connection is closed.
I have sniffed the net and I have find a TCP message with the RESET bit =1 (TCP level), sent by the remote station or the...
ucp51
Dear all,
i'm trying to send a SMS though a SMSC communication based in EMI-UCP protocol, and i'm getting this error message:
emi_decode: len 36 RX-BUF:<02>01/00034/R/51/N/06/ AdC invalid/1C<03>
and the SMS is not sent.
What could the reason be?
A lot of thanks.
Daniel P.
iec 870-5-104
Dear all,
I am receiving after a set-point command ( C_SC_NA_1 in IEC 870-5-104 protocol ) two confirmation messages with differents COTs (Cause of Transmission):
1- COT=7 -> Activation confirmation
2- COT=10 -> Activation termination.
And then these set points commands are not...
Openlink comm error
Hi,
I have an Openlink (Version year 1997) communication under Solaris.
My C Openlink client connect with a Java Openlink Server. It connects and sends the first message, but then when it tries to send the second one, an error occurs: 'Bad file number'
This is the error...
soe allen bradley
Hi,
I'm going to use SOE module with 1ms of input resolution in my project.
I don't know If I need to include in each PLC system a GPS to convert the CST tiem to the UCT time format.
Could I use another time reference that not be the GPS time master, i.e. the PLC master time?
cybergraphy
The GPRS clients must communicate under IEC 60870-5-104 protocol.
I have an Allen Bradley PLc, which sends data to a IEC 104 Interface module, which has to send the data to a GPRS gateway.
Which GPRS gateway must I use?