Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by CapBlack

  1. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    01 Jan 2010 17:24 Potyo work on MPLAB 8.43 !! -------------------------------------------------------------------------------- HI all , I do a copy folder ICD2 from ver 8.00 to ver 8.43 and magic ... MPLAB ICD 2 Ready Programming Target... ...Validating configuration fields...
  2. C

    Potyo work on MPLAB 8.43 !!

    HI all , I do a copy folder ICD2 from ver 8.00 to ver 8.43 and magic ... MPLAB ICD 2 Ready Programming Target... ...Validating configuration fields ...Erasing Part ...Programming Programming Executive ...Verifying Programming Executive ...Programming Program Memory (0x0 - 0x12FF) Verifying...
  3. C

    How to get Potyo work on Mplab 8.14?

    Re: Potyo and Mplab 8.14 No one ?
  4. C

    How to get Potyo work on Mplab 8.14?

    Hi all ,my question is how to get potyo work on Mplab ver 8.14 y need to work on new devices dspic33 tanks.
  5. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    hi , i found potyo no work on MPLAB more than ver 8 ? MPLAB ICD 2 Ready Connecting to MPLAB ICD 2 ...Connected Setting Vdd source to MPLAB ICD 2 Target Device dsPIC33FJ32GP202 found, revision = Rev 0x3001 ...Reading ICD Product ID Running ICD Self Test ...Passed MPLAB ICD 2 Ready Programming...
  6. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    Hola elmasvital te contesto en espanol para decirte que por la pagina 15 mas o menos hay una version smd igual que la ver truhole busca por alli , los transistores no son criticos podes usr el mismo circuito con todos sus valores solo smd chau ...
  7. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    hi all again , no luca I have made 2 cables 25 cm and 10 cm bots same problem take a look on the error the program pass but the debugger no ... regards cap.
  8. C

    [SOLVED] Project to replace CY7C64613 in the ICD2

    hi ,can some one help with this problem , i make the potyo ICD and .... Connecting to MPLAB ICD 2 ...Connected Setting Vdd source to target Target Device dsPIC30F3014 found, revision = Rev 0x1001 ...Reading ICD Product ID Running ICD Self Test ...Passed MPLAB ICD 2 ready for next operation...
  9. C

    Cant program pic 18F4550 with icd2

    Hi ennio ok i have ICD2 serial ready and he's working fine, now i maked a new one with USB pic 18F4550 i tryed it but i cant program it well with the ICD2 serial. Thx.
  10. C

    Cant program pic 18F4550 with icd2

    Hi all , i cant program the pic 18F4550 with icd2 serial stoolz some one can help ? to do this . I have build Pics and Potyo2 new one and nothing work Thanks in advance regards,
  11. C

    ICD2 Stolz and dsPIC30F3010

    pickit2 debug dspic30f config word Hi , nothig ... the unit 30F3010 maybe was damage I check it later
  12. C

    ICD2 Stolz and dsPIC30F3010

    pickit2 dsp30f HI all , I get the new unit and 30F3014 and surprise Stooz ICD2 Connecting to MPLAB ICD 2 ...Connected Setting Vdd source to target Target Device dsPIC30F3014 found, revision = Rev 0x1001 ...Reading ICD Product ID Running ICD Self Test ...Passed MPLAB ICD 2 Ready Tanks all CapBlack
  13. C

    ICD2 Stolz and dsPIC30F3010

    dspic avdd avss Hi all , only remember one thing I have exactly Stolz clone without buffers on PG & PC because of that i wanted to use dsPIC30F . i have been checking all coneccions which includes AVdd & AVss and they are fine. tomorow i wil try again with a new unit because maybe the first one...
  14. C

    Optical Isolation of an Analog Signal

    7b41 analog signal optical isolator circuit Hi , I used one time IL 300-G , analog optocupler check it out .
  15. C

    ICD2 Stolz and dsPIC30F3010

    icd2 dspic pgc2 HI again thanks to all 4 help , I dont know Hugo the line dsP30F are electrical = to 18F if u mean 24F and 33F I agree with you . CapBlack