Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.
HI,
How to use tranformer in proteus ?? i want to use a 12/220v transformer @50hz but it is asking for primary inductance seconary nductance etc how to get those values.
HI abc_de
i am not able to find uf4007 in proteus.Can u plese suggest some replacement for it also changed the bootstrap capacitor to 2.2uf but still same issue.
- - - Updated - - -
hi
i got uf4004 n im getting result for few min but then it gave this error and stopped
hi,
while simulating this circuit in proteus it gives some error im unable to understand how to rectify this the circuit and ther error is attached. plese tell me what is the error and how to rectify this the input to the inverter h bridge is 20v dc ir2110 vcc is 15v dc
error
Thanks KlausST
do you mean like this
i hve modified the image according to mu understanding.
also high side out put to be seen accross HO pin and COM(GND) ?? Is this correct ?
- - - Updated - - -
thanks klausST i got the out put . now im moving towards power stage . i will return with...
this my ir2110 ckt am i doing something wrong im not getting proper out put please sugeest some changes needed
- - - Updated - - -
i made a little modification in above ckt
low side output
high side output
plese tell me what am i doing wrong not getting high side output
https://obrazki.elektroda.pl/8203938900_1493439663.jpg
this is my current inverter testing set up probe is normal probe
in this case do i need any isolation transformer to keep my dso safe . if i need sonthing please guide me how to keep my dso safe im using tbs2072
if i use 220/220v isolation transformer with 100W power. the connections will be like ine side of transformer will be connected to probe + and gnd . and the other side will serve as testing points . Then no need to worry about connections gets accidently reversed ?? I hope this is what u ment ...
what is this isolation transformer??
can u please explain with the help of a diagram on how to use isolation tranformer while testing mosfert output with normal probe.
thanks in advance for your help
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.