Welcome to our site! EDAboard.com is an international Electronics Discussion Forum focused on EDA software, circuits, schematics, books, theory, papers, asic, pld, 8051, DSP, Network, RF, Analog Design, PCB, Service Manuals... and a whole lot more! To participate you need to register. Registration is free. Click here to register now.

Recent content by aeytr

  1. A

    Can't read negative voltage values

    Hi, I built an ECG circuit that works fine. Now I want to read ECG signal via arduino analog pins(I m usingpro mini/5V/16Mhz). The problem is I cant read negative voltage values. I tried some methods but none of them worked. Can you please help? Thanks. Regards. Ali Emre
  2. A

    HM-10 Bluetooth Module problem / wireless EMG transfer

    No,that was an ECG circuit. Circuits are similar but this is not about it.
  3. A

    HM-10 Bluetooth Module problem / wireless EMG transfer

    Thanks for reply, I think the problem is the crcuit connection. Because when I touched the EMG signal output pin to HM10, I cant see anything on the EMG circuit output. All I can see is zero avarage noise that is what I get from bluetooth signal, all zeros. Actually bluetooh module broadcasting...
  4. A

    HM-10 Bluetooth Module problem / wireless EMG transfer

    Hello, I have a EMG circuit with 3 electrodes. I wanna send the EMG signal via bluetooth. and I am using HM-10 for that purpose. At first, I have to say that I can broadcast a signal which is the voltage alteration on potetiometer. (Relevant circuit is given below.) That was just a test...
  5. A

    How to remove EMG artifacts from ECG?

    Thanks for information. I'll jus adjust my filters better. Thanks again. I have 2nd order notch filter for both mains electricity and EMG. I'll check my calculations again. Thank you.
  6. A

    How to remove EMG artifacts from ECG?

    Understood. Thanks for the replies.
  7. A

    How to remove EMG artifacts from ECG?

    Hi, Thank you for your useful response. I am a little unexperienced. Actually I dont even know how to add more electrodes. I guess, I should add more AD620XX and then use MUX but that is jus a guess. Do you have any books or something like that based on adding more electrodes? Thank you again...
  8. A

    How to remove EMG artifacts from ECG?

    Actually that is my referance circuit. I just changed AD705J with its equivalent(OP07) and added a notch filter to output. And my 0.03Hz HPF has 1000uF cap and 5k6 res. I can't see any differance.
  9. A

    How to remove EMG artifacts from ECG?

    Hello, I built a circuit that aquires ECG from electrodes on chest. When the subject is stable, I can get ECG with enough accuracy. But when the subject moves or takes a deep breath, I am getting a ECG mixed with EMG. I though my filters are okay, but apparently they're not. In short, I m...
  10. A

    ECG circuit design with AD620

    Hi, I am triying to built similar ECG circuit. But i stuck at iisolation side. Can you please help with that. Can you advise an example referance design of an ECG circuit for me. Thank you. Best Regards.
  11. A

    ECG circuit design with AD620

    I designed notch filter using LM358, but it not quite right. Did you analyze di freq response? Did it really worked? Would you please share the prospice output? Thanks. Ali,