ericmar
Joined: 14 Apr 2004 Posts: 279 Location: Singapore
|
01 Sep 2004 5:27 Problem about the 74LS90 Decade counter |
|
|
|
|
Hi guys,
for some reasons the counter doesnt start from 0 but 8. It does count correctly except that it start from 8. I hv no idea why it is like this???
Thanks for any help.
Regards,
Eric
|
|
| Back to top |
|
 |
echo47
Joined: 07 Apr 2002 Posts: 4205 Helped: 565
|
01 Sep 2004 6:23 Problem about the 74LS90 Decade counter |
|
|
|
|
| When you say "start", do you mean power-up? The 74LS90 does not have a power-up clear feature, so it powers-up into an undefined state. You must apply a reset pulse to guarantee zero.
|
|
| Back to top |
|
 |
House_Cat
Joined: 21 Feb 2002 Posts: 1392 Helped: 292
|
01 Sep 2004 6:39 Re: Problem about the 74LS90 Decade counter |
|
|
|
|
There are two different resets on the 74LS90 - or I should say a master set and a master reset.
Pins 2 and 3 are master reset and will clear the 74LS90 to zero. High on pins 2 and 3 with pins 6 and 7 low will clear to zero.
Pins 6 and 7 are master set and will set the 74LS90 to nine. High on pins 6 and 7 with pins 2 and 3 low will set to nine.
Master set and master reset should be held low to count.
|
|
| Back to top |
|
 |