| Author |
Message |
Wowee
Joined: 17 Jul 2002 Posts: 21
|
31 Aug 2004 10:05 How quantify the Signal Integrity? |
|
|
|
|
Hi,
There is some overshoot and ringing in a signal when I debug a circuit.What amplitude the overshoot and ringsing do not exceed so as to I can ignore them? thanks everybody
|
|
| Back to top |
|
 |
brmadhukar
Joined: 21 Jun 2002 Posts: 844 Helped: 29
|
03 Sep 2004 5:20 Re: How quantify the Signal Integrity? |
|
|
|
|
Hi,
You cannot do anything about the ringing and overshoot if the circuit is fixed. As long as it is not bothering your operation do not worry about it. You have to measure when this is affecting your circuit functionality. If affecting, change the circuit.
B R M
|
|
| Back to top |
|
 |
Google AdSense

|
03 Sep 2004 5:20 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
delay
Joined: 11 Jun 2004 Posts: 219 Helped: 3 Location: Van Allen Belt
|
04 Sep 2004 12:04 Re: How quantify the Signal Integrity? |
|
|
|
|
| You put a 50 Ohm resistor on the signal line that has ringing such as clock line. This will help dissipate some energy in the resistor and overshoot may subside a little.
|
|
| Back to top |
|
 |
chinara
Joined: 15 Sep 2004 Posts: 96 Helped: 2
|
29 Sep 2004 5:25 Re: How quantify the Signal Integrity? |
|
|
|
|
| Because overshoot will increase crosstalk noise, attenuating the overshoot may be considered. In my view, the 50om resistor, maching the source resistance at the source terminal, might be a little large. I think the 33 or 22 might be better.
|
|
| Back to top |
|
 |