How to decide Waveport size of a CPW and Batch mode in HFSS


Post new topic  Reply to topic    EDAboard.com Forum Index -> Electromagnetic Design and Simulation -> How to decide Waveport size of a CPW and Batch mode in HFSS
Author Message
pnayak1



Joined: 04 Nov 2009
Posts: 1
Location: ASU, Tempe, AZ


Post04 Nov 2009 23:51   

How to decide Waveport size of a CPW and Batch mode in HFSS


Hello,

I am new to HFSS, I am using HFSS v11.2 on Windows XP. I am trying to design a CPW with 50 ohm char impedance within a frequency range of 1GHz to 100GHz. Ultimate aim is to make the onwafer calibration structures for TRL measurements at various freqs. The substrate resistivity is 0.1 MΩ and thickness is 725µm, there is an Oxide coating on top of it with thickness = 145nm. The CPW is on top of this oxide layer. It is a Ground Signal Ground confign, All lines are 1µm thick. I am using half of the structure (i.e one Ground line and half the width of the signal line) with PerfH on all sides and targeting 100Ω (so that the full structure gives 50Ω). I am running a freq sweep from 1 GHz to 100 GHz with 10 step increment. The substrate size is 1mmx2mm and the airbox is 1mmx1mmx10mm. I am varying the gap between G and S and the width of the lines to achieve 100Ω for half structure for all freqs in 1GHz to 100 GHz range.

1. I am not sure what is the optimum size of the waveport. Whether I should use a large waveport with Height=4mm and width=2mm or a smaller waveport with H=500µ and W=300µ. How do I decide the optimum size of the waveport?

2. Is there anyway I can run HFSS in batch mode, so that it runs for different combinations of Width of the lines and the gap between them and store the results in separate files which I can analyze later. Instead of manually changing the line widths and gap and waiting for 1hr for the sweep to get over.

I have attached my HFSS file. It will be very helpful if I can get an early response.

Thank You for your time,
Pinak
Back to top
Google
AdSense
Google Adsense




Post04 Nov 2009 23:51   

Ads







Sorry, but you need login in to view this attachment

Back to top
kosolson2005



Joined: 22 Feb 2008
Posts: 14


Post19 Nov 2009 17:01   

Re: How to decide Waveport size of a CPW and Batch mode in H


Can someone please help out with this problem? I am also curious about this question.


Thank you in advance.
Back to top
crayon



Joined: 06 Nov 2008
Posts: 8


Post21 Nov 2009 22:43   

Re: How to decide Waveport size of a CPW and Batch mode in H


1. There is a tutorial on CPW port definition given by Ansoft. It is everywhere on the web. I would do comparison between simulation and measurement to determine the best configuration.

2. Create a parameterized design and do parameter sweep.
Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> Electromagnetic Design and Simulation -> How to decide Waveport size of a CPW and Batch mode in HFSS
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
waveport size for Grounded-CPW simulation help!!! (6)
how to decide W and L size? (5)
batch mode for HFSS (2)
Please help me decide hfss cpw-fed antenna simulation result (2)
hfss cpw size with very thick substrate (3)
how to decide die size? (4)
power CPW mode in HFSS (2)
How to run Feko in batch mode? (1)
How to force a signal in ncverilog sim. through batch mode? (2)
HFSS background and waveport (13)


Abuse || Administrator || Moderators || Support us || sitemap
topic RSS