buenos



Joined: 24 Oct 2005
Posts: 657
Helped: 15
Location: UK


Post02 Nov 2009 21:56   

microvias in allegro 16.2


hi

1.
how to create a microvia in allegro? step-by-step, please
in the pad designer program, there is an option for "microvia", just it is not available, which means its gray, i can not enable it. why?
actually it says type=through and there is no option to change it to BB via. microvia would be a BB via, i think.

2.
how to create a stacked via structure with 2 microvias from top to inner-1 and a big buried tht via from inner-1 to layer N-1. ?

which allegro documents describe this?
a few allegro pdfs talk about these, just they dont tell me where to click in the menus to do it.
Back to top
lhademmor



Joined: 22 Oct 2008
Posts: 59
Helped: 6


Post03 Nov 2009 13:40   

Re: microvias in allegro 16.2


1)
A) Crate the via as a standard through via.
B) microvias in allegro 16.2
This window shows how to setup vias as either blind or burried.


2) In constraint manager setup to use these new via types and set stacking to all allowed. Under analyse menu, choose modes, and look for the tap where stacking is mentioned, and set it 0 and 0 (min max).

PDF's ? Algroroute.pdf, in chapter 4.
Back to top
buenos



Joined: 24 Oct 2005
Posts: 657
Helped: 15
Location: UK


Post03 Nov 2009 21:08   

microvias in allegro 16.2


thanks.

i cant really find the option for stacking allowed.
what is "0 and 0 (min max)" ? bb via stragger? what is it anyway?
Back to top
lhademmor



Joined: 22 Oct 2008
Posts: 59
Helped: 6


Post04 Nov 2009 14:21   

Re: microvias in allegro 16.2


I did a flaw, it was not under analyse and modes, but under physical - physical constraint set - all layers. out in the most outer right part.

microvias in allegro 16.2


max and min is center hole to center hole distance, as having vias stacked on top of each other, You should state nill = 0. Max distance ?? Hmm i don't know whats that is good for, but i allways state 0 Smile. for non stackted vias 0.3 should be set as min.
Back to top
Google
AdSense
Google Adsense




Post04 Nov 2009 14:21   

Ads




Back to top
buenos



Joined: 24 Oct 2005
Posts: 657
Helped: 15
Location: UK


Post04 Nov 2009 21:17   

microvias in allegro 16.2


hi

thanks.

is there an option to make 2 microvias to go to second layer, then one THT from there. or do i have to make the second microvia manually? for example power or gnd connection for a micro-BGA chip
Back to top
lhademmor



Joined: 22 Oct 2008
Posts: 59
Helped: 6


Post09 Nov 2009 23:59   

Re: microvias in allegro 16.2


imagine 10 layers.

Then You have a 0.1mm drilled and 0.3mm pad via, and a 0,25mm drilled and 0.6m pad via.

under setup - configure BB vias You make a Layer01-Layer02 via copied from microvia, then a Layer02-Layer03 also copied from microvia, now a Layer03-Layer08 copied from large via and equal from bottom side.

In the constraint manager You setup stacking for Your needs and for what the manufacturing farm demands.
Back to top
buenos



Joined: 24 Oct 2005
Posts: 657
Helped: 15
Location: UK


Post10 Nov 2009 0:51   

Re: microvias in allegro 16.2


i think you misunderstood me, or i misunderstand you.

what i wanted:

Code:


-----                        <-- SMT pad
V  V                        <-- 2 microvias
-----------
       I   I
       I   I                  <-- 1 THT via
       I   I
       I   I
       I   I
     -------

-

Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> PCB Routing & Schematic Layout software & Simulation -> microvias in allegro 16.2
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
Using Allegro 15.7's footprint for Allegro 15.2 (6)
anyway to convert allegro 16 version to allegro 15.7? (1)
Allegro (8)
allegro (1)
Allegro 16.0 (2)
Allegro 14.2 (2)
Allegro 16.2 (1)
allegro to protel (2)
Allegro help? (2)
Translation to Allegro (4)


Abuse || Administrator || Moderators || Support us || sitemap
topic RSS