binojkumar
Joined: 19 Jul 2004 Posts: 75 Helped: 1 Location: Bangalore
|
28 Oct 2009 10:55 Thyristers |
|
|
|
|
Hi friends im doing a project that controls temperature of a heating coil.
the heating coil power supply is connected through thyrister and a PWM out put is controlling this Thyrister. This is my application. the heating coil is operated in AC. So what kind of thyrister i should use? please suggest thyrister and a driving circuit.
VC
|
|
| Back to top |
|
 |
pranam77
Joined: 22 Apr 2008 Posts: 1071 Helped: 94 Location: Mangalore(India)
|
28 Oct 2009 14:09 Re: Thyristers |
|
|
|
|
| binojkumar wrote: |
| Hi friends im doing a project that controls temperature of a heating coil. the heating coil power supply is connected through thyrister and a PWM out put is controlling this Thyrister. This is my application. the heating coil is operated in AC. So what kind of thyrister i should use? please suggest thyrister and a driving circuit.VC |
I got confused a bit with the question. First of all if you are operating the load with AC, the PWM technique will not work. You need to go with Phase controlling technique. You may use BT136 or BTA12/600 Triacs for operating heating loads on AC. Cheers
|
|
| Back to top |
|
 |
Naveed Ahmed
Joined: 31 Aug 2008 Posts: 22 Location: Pakistan
|
31 Oct 2009 17:50 Re: Thyristers fordriving a heating coil |
|
|
|
|
You can use solid state relay for that purpose.
Use MOC3023 optocoupler and drive a triac BTA16 through that optocoupler. And control PWM through it.
Regards
Naveed Khowaja
|
|
| Back to top |
|
 |
Google AdSense

|
31 Oct 2009 17:50 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
betwixt
Joined: 04 Jul 2009 Posts: 388 Helped: 64 Location: Wales, UK
|
31 Oct 2009 20:27 Re: Thyristers fordriving a heating coil |
|
|
|
|
I agree with pranam77, what is the purpose of using PWM to control a Triac, it only needs one pulse per quadrant to turn it on and it turns itself off at zero crossing point.
You must use phase control not PWM.
Brian.
|
|
| Back to top |
|
 |
FvM
Joined: 22 Jan 2008 Posts: 5161 Helped: 767 Location: Bochum, Germany
|
01 Nov 2009 9:17 Thyristers fordriving a heating coil |
|
|
|
|
EMC rules require higher power heating controllers not to use phase control but full wave switching.
It can be either operated as a slow PWM with a few seconds period, which is the classical method, or in a
SD modulator style.
|
|
| Back to top |
|
 |
betwixt
Joined: 04 Jul 2009 Posts: 388 Helped: 64 Location: Wales, UK
|
01 Nov 2009 10:35 Re: Thyristers fordriving a heating coil |
|
|
|
|
I think we need Binojkumar to tell us more.
If their intention is to control the current flow as accurately as possible, they have no option but to use phase control and trigger the Thyristor once per cycle. If they intend to maintain an average temperature but it can be allowed to rise and fall around a center point, they can use slow PWM to emulate a mechanical thermostat.
I suppose both solutions are applicable under the right circumstances but which is optimal depends on the project requirements.
I would still use a Triac in preference to a Thyristor though.
Brian.
|
|
| Back to top |
|
 |
FvM
Joined: 22 Jan 2008 Posts: 5161 Helped: 767 Location: Bochum, Germany
|
01 Nov 2009 12:58 Re: Thyristers fordriving a heating coil |
|
|
|
|
| Quote: |
| both solutions are applicable under the right circumstances |
In the EU, EN61000 restricts the application of phase control for heating applications to power up to 200 W.
I guess, that similar regulations apply for the US and other countries.
I also don't agree, that PWM neccessarily involves temperature fluctuations. Even in analytic instruments, that are very
sensitive to temperature variations, e.g. gas chromatography column ovens, full wave control works with good results.
The reason is, that only few heatings "plants" have time constants below 1 sec. and effectively none below 200 ms.
In the latter case, the said SD modulator method still produces acceptable control quality.
|
|
| Back to top |
|
 |
betwixt
Joined: 04 Jul 2009 Posts: 388 Helped: 64 Location: Wales, UK
|
01 Nov 2009 13:26 Re: Thyristers fordriving a heating coil |
|
|
|
|
Binojkumar doesn't tell us what the coil is used for. Perhaps the load it imposes is below the 200W restriction.
Do you know why EN61000 was introduced? I have no idea although I suspect it is something to do with asymetric loading of AC lines. I remember trials many years ago when applying a DC offset to street lighting supplies was tried as a method of turning all the lights on or off from a central control box. It worked fine in theory but at the time it was commonplace to use SCR PSUs in domestic TVs and the half cycle loading they made on the mains supply was enough to unbalance the +/- AC cycles and the street lights followed TV program popularity!
Brian.
|
|
| Back to top |
|
 |
FvM
Joined: 22 Jan 2008 Posts: 5161 Helped: 767 Location: Bochum, Germany
|
01 Nov 2009 13:45 Thyristers fordriving a heating coil |
|
|
|
|
The title is Limits for harmonic current emissions. Avoiding possible interference with ripple control receivers is only one of several motivations.
Because phase control can't be easily eliminated in lighting control, it's still allowed there, but harmonic limits require some filtering. For applications, that effectively don't need phase control, the harmonic limits are so low, that the filtering effort would be inpracticable.
|
|
| Back to top |
|
 |