pll circuit design


Hi,

I wish to know if there is any other circuit in PLL which is sensitive to supply voltage apart from VCO.

As I have an problem with my PLL as it is only able to lock back after a long time ( ~ 5minutes) or if I reduce the VCO supply voltage. Do you guys have any idea of which circuit which might possible cause this problem?

BTW, the PLL is combination of PLL and CDR block.

Thanks.
Back to top
Google
AdSense
Google Adsense




Post29 Jul 2009 12:27   

Ads




Back to top
yellowperil



Joined: 18 Nov 2008
Posts: 6


Post31 Jul 2009 6:44   

supply insensitive pll design


Hope that this can give a clearer picture and advice from you guys.

Initially my PLL can lock to the reference clock (160MHz) using PFD and weaker Charge Pump. After lock to reference clock, the PLL switch to the Phase Detector and stronger Charge Pump. During this time, some mismatch in the input data, cause the PLL to increase its frequency until it is clamped by VCO max operating limit, 250MHz (which is VCO supply voltage). When switch back to the PFD circuit when VCO operate at 250MHz, it is only able to lock back after a long period.

Do you guys have any idea of which circuit which may potentially cause this to happen. Thanks.
Back to top
dick_freebird



Joined: 04 Mar 2008
Posts: 312
Helped: 45
Location: USA


Post01 Aug 2009 15:30   

pll circuit


Charge pump leakage ("stronger" = "leakier")? could be pushing
the loop out of lock; transient misbehavior in switching all that
stuff between modes, might introduce a large charge-slug, a
design "oops" might introduce a phase inversion or skew, etc.
Changing charge pump strength might make the loop filter go
unstable. Loop amplifiers with non-rail-to-rail input range might
show phase inversion or input pair choke-off if the pump node
swings too wide.

Recommend you break the loop after capturing the pump and
VCO control node voltages aboutt the point of switchover, and
try to pare down the possibilities rather than collecting a whole
basket of conjecture.
Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> Analog Circuit Design -> PLL circuit sensitive to supply voltage
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
Need an AC supply automatic voltage stabilizer circuit (1)
MAX232 voltage supply - need help in a circuit (6)
How to get negative voltage supply from +DC Voltage supply (3)
How to get negative voltage supply from +DC Voltage supply (3)
ac supply automatic voltage stabilizer circuit 100-270v inpu (2)
design a temperature sensitive circuit..... (10)
Circuit or an IC that is sensitive to pulse frequency change (3)
convert voltage or current signal to power supply voltage.. (1)
breakdown voltage vs. voltage supply (3)
PLL power supply noise rejection (4)


Abuse || Administrator || Moderators || Support us || sitemap
topic RSS