Post01 Jul 2009 8:27   

sim300s_v6


hi,

iam using SIM300S_V6.01 module,in that iam using serial port 1 all signals.iam trying to send AT commands to the module.but it is not sending any response to that particular commands.pls hep me regarding this issue.
Back to top
GSM Man



Joined: 15 Apr 2009
Posts: 357
Helped: 46
Location: New Jersey, USA


Post01 Jul 2009 14:56   

SIM300S_V6.01


Can you provide more details on what you are sending? What platform (PC or microcontroller)? How do you know the module is receving the data - have you verified with a scope?
Back to top
sidhu_roy2005



Joined: 28 May 2008
Posts: 4


Post02 Jul 2009 10:29   

Re: SIM300S_V6.01


the AT commands are sended through 16-bit uc via CPLD.iam sending the command only AT to GSM.this signal is seen through the scope.but iam not getting the response from the module.the pk-pk voltage is 3.3Vmax.in idle state the TXD signal is high(3.3V approx).SIM300 module supply is approx of 4.2V.

when i send Reset signal the module is turned on.this can be verified by SIM_CLK signal and SIM_VDD 2.9V generation.

help me regarding this issue.
Back to top
Google
AdSense
Google Adsense




Post02 Jul 2009 10:29   

Ads




Back to top
GSM Man



Joined: 15 Apr 2009
Posts: 357
Helped: 46
Location: New Jersey, USA


Post02 Jul 2009 12:10   

Re: SIM300S_V6.01


sidhu_roy2005 wrote:
iam sending the command only AT to GSM.
Are you sending a Carriage Return after the "AT"?
sidhu_roy2005 wrote:

when i send Reset signal the module is turned on.this can be verified by SIM_CLK signal and SIM_VDD 2.9V generation.
When you say "Reset" signal, do you mean the "PWRKEY" pin? The "VDD_EXT " pin will go high when the module has powered-up. Also the "Network LED" pin should start toggling.
Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> Professional Hardware and Electronics Design -> SIM300S_V6.01 - problem with sending AT commands
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
Sending and receiving AT commands on 89c2051 (2)
Sending Commands to Keyboard from PIC 18F452 (1)
sending, receiving, comparing SMS through AT commands (26)
I need just a small help in AT Commands of sending sms (37)
nokia mobile phone problem with at commands? (5)
Problem in Sending sms through PC(hyper terminal) (5)
SIM300 EVB AT commands problem (1)
problem of sending sms w 8051 and Siemens C55 (1)
gsm/gprs problem - sending image to mobile as MMS (1)
Sending an F-bus frame to a nokia phone via USART problem (1)


Abuse || Administrator || Moderators || Support us || sitemap
topic RSS