| Author |
Message |
mustangyhz
Joined: 18 Nov 2008 Posts: 32
|
23 Jun 2009 8:20 lvs different numbers of ports |
|
|
|
|
1# invert.lvs.report:
Error: Different numbers of ports.
Error: Power or ground net missing.
......
Layout Source Component Type
------ ------ --------------
Ports: 0 4 *
Nets: 6 4 *
Instances: 1 0 * MN (4 pins)
1 0 * MP (4 pins)
0 1 * INV (2 pins)
2#chrt018.laymap.cal
LAYER MAP 30 TEXTTYPE 10 1030 // Poly2 Labels
LAYER POLY2TXT 1030
LAYER MAP 34 TEXTTYPE 10 1034 // Metal1 Labels
LAYER M1TXT 1034
......
ATTACH POLY2TXT gply
ATTACH M1TXT M1_nodev
ATTACH M2TXT M2_nodev
3#techfile1.tf
( ("Metal1" "label") 34 10 t )
( ("Metal1" "Blockage") 34 5 t )
from 1, we can know ports are missing, from 2 and 3, we should use ( "Metal1" "label" ). Following these, i still failed. why? elp!!
Added after 5 hours 42 minutes:
It has been solved. we should use ( "Metal1" "label" ).
|
|
| Back to top |
|
 |
ghayas1981
Joined: 17 Sep 2008 Posts: 27
|
03 Sep 2009 5:59 calibre lvs layout ports missing in the source |
|
|
|
|
Hi,
im having the same problem
please let me know the details to solve this problem
thanking in anticipation
|
|
| Back to top |
|
 |
wangyg
Joined: 08 Apr 2009 Posts: 4
|
14 Sep 2009 17:17 different numbers of ports lvs |
|
|
|
|
I am facing the problem also,
Did anyone solve it ?
Thanks very much,
|
|
| Back to top |
|
 |
Google AdSense

|
14 Sep 2009 17:17 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
mustangyhz
Joined: 18 Nov 2008 Posts: 32
|
13 Oct 2009 8:48 calibre+lvs+Different numbers of ports |
|
|
|
|
| you should select the correct layer for port lable.
|
|
| Back to top |
|
 |