Gnding between earth gnd and power suppy gnd


Post new topic  Reply to topic    EDAboard.com Forum Index -> Electronic Elementary Questions -> Gnding between earth gnd and power suppy gnd
Author Message
boats_ranger



Joined: 26 Apr 2009
Posts: 5


Post26 Apr 2009 17:36   

earth gnd


Hi, Is there a perfered method connecting earth gnd to a low voltage power supply and circuit boards?

Normally, I would connect the earth gnd and power supply together at the AC input of the low voltage power supply. I would then connect that gnd to the case.
I would then fan out low voltage power and gnd to the other circuit boards.

It seems the return path for current who source is the 5 volts would be the 5volt ground. The 5v power is derived from ac, who's return path is back to the ac mains using the neutral as the path.

I have recently seen earth ground faned out to each pcb in a parellel fashion.
Is there a benifit to this layout? would this create two gnd loops?
Back to top
Kral



Joined: 28 Mar 2005
Posts: 1182
Helped: 187


Post26 Apr 2009 20:12   

power supply dirty earth


boats_ranger,
Your concern about ground loops is justified. "Daisy Chaining" the Earth ground to several PCB boards is not a good idea. The "star" grounding scheme is almost always the best one to use. In this scheme, all power supply grounds are connected together at one point only.
Regards,
Kral
Back to top
bws



Joined: 29 Apr 2007
Posts: 20
Location: Denmark


Post26 Apr 2009 20:52   

Gnding between earth gnd and power suppy gnd


i always connect the DC supply GND to the Earth GND wiht a 1-5Mohms resistor, or a capacitor whit a high Xc to 50hz/60Hz and low on HF, and use the DC supply GND to the Chassis/case...
Back to top
Google
AdSense
Google Adsense




Post26 Apr 2009 20:52   

Ads




Back to top
boats_ranger



Joined: 26 Apr 2009
Posts: 5


Post27 Apr 2009 0:18   

Re: Gnding between earth gnd and power suppy gnd


I have not used a 1meg ohm resistor from power supply gnd to earth gnd.
My thought are: if the return current paths have low impedance then the voltage drop would be mineral, with the benefit of lower noise. From experience, earth ground seem to add noise to my system, so I can understand using a isolation strategy between the two gnds.

I can rationalize (right or wrong) a connection through a inductor or a low resistant& (100 -150 ohms.) What are the benefits of connecting the two gnds through a high impedance?
Back to top
ferdie444



Joined: 23 Sep 2007
Posts: 4
Helped: 1


Post28 Apr 2009 16:01   

Re: Gnding between earth gnd and power suppy gnd


yap,i agree w/ kral to use star grounding system to keep it intact and less prone from loose connection unlike the daisy chain grounding,because once you have a loose ground connection noise will be generated from your system.and @ the same time i agree w/ bws to use resistor or capacitor for the dc voltage before connecting to the chassis ground from which the ac is connected because,dirty ground is high voltage and clean earth is (low voltage grounding dc) and it's not a good practice to mix the two grounding system together,otherwise noise will be generated again.thanks and more power.....
Back to top
boats_ranger



Joined: 26 Apr 2009
Posts: 5


Post12 May 2009 14:28   

Re: Gnding between earth gnd and power suppy gnd


because,dirty ground is high voltage and clean earth is (low voltage grounding .

Can you explain what is ment by "dirty ground is high voltage"

thanks
Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> Electronic Elementary Questions -> Gnding between earth gnd and power suppy gnd
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
GND (analog-gnd, digital-gnd, earth-gnd) MUST = 0V? (15)
Why do we need an RC between GND and Chassis GND? (1)
About noise in analog GND and digital GND . (5)
Analog GND <-> Digital GND = how to place both GNDs o (8)
wire from Digital GND to Analog GND reduce noice (5)
Difference between GND and PGND (6)
HELP!!! ANALOG GND Vs DIGITAL GND (7)
difference between analog and digital gnd (1)
So small a resistor between core supply voltage pin and GND! (4)
The low resistor between statixII chip's 1.2v pins and gnd ? (4)