30 Jul 2008 13:40 thermal relief and copper pour |
|
|
|
Hey
I use orcad layout for my PCB designs. In one particular design i have used a
copper pour as a ground plane, and in the process i have attached it to ground pins using the net attach. In orcad it places this ground net attach as spokes to the copper pour, however the lines are extremely thin (not manufacturable). I want to increase the width of these spokes. How should i do this?
Thanks
Mike
|
|
| Back to top |
|
 |
FvM
Joined: 22 Jan 2008 Posts: 2679 Helped: 438 Location: Bochum, Germany
|
30 Jul 2008 14:03 thermal relief and copper pour |
|
|
|
| All PCB tools I've been working with had parameters for it, I'm pretty sure that's also the case with Orcad. The setting may be either global or more likely individual for each copper pour object.
|
|
| Back to top |
|
 |
mlkcampion
Joined: 30 Jul 2008 Posts: 4
|
30 Jul 2008 15:43 Re: thermal relief and copper pour |
|
|
|
Thanks
Yes i have found the Thermal relief settings, in this dialog box there are settings for
Small Thermall Releif and Large Thermal Relief. Bit lost on why there is 2 settings.
The options you are given are:
Annular Overdrill
Isolation Width
Spoke Width
Firstly iam not sure which iam working with small or large because when i was doing the copper pour and did the net attach I didn't intend the attachment to be a "thermal relief" but it seems there is an obvious connection between the two operations. I dont know if this is the case in all EDA tools.
I have tried changing some of the settings in the dialog box and the spokes did get larger but the settings have gone back to a default setting in the dialog box however the spokes have remained large, so again confusion as to the link between the dialog box and what i am seeing on the layout?
Thanks
Added after 1 hours 13 minutes:
Ok so Spoke width is definately the setting required, i increased the size again and it worked after i did a redraw/refresh, but it won't let me make the spokes smaller? This seems to be an orcad issue.
|
|
| Back to top |
|
 |
FvM
Joined: 22 Jan 2008 Posts: 2679 Helped: 438 Location: Bochum, Germany
|
30 Jul 2008 16:13 Re: thermal relief and copper pour |
|
|
|
| With other tools, there is typically also an option to disable thermal isolation for individual pads and for the copper pour as a whole.
|
|
| Back to top |
|
 |
kender
Joined: 19 Jun 2005 Posts: 965 Helped: 70 Location: Stanford, SF Bay Peninsula, California, Earth, Solar System, Milky Way
|
02 Aug 2008 1:18 Re: thermal relief and copper pour |
|
|
|
| FvM wrote: |
| With other tools, there is typically also an option to disable thermal isolation for individual pads and for the copper pour as a whole. |
I've seen this option in P*otel, but I couldn't find it in OrCAD 10.5
|
|
| Back to top |
|
 |