Post10 Jun 2008 11:49   siemens - C7 - OP

Does anybody know, How should I put a siemens C7-634 op, into Transfer mode?!?!?!? Question

I used UP+ESC for C7-633. But for C7-634 I can not do this.
Thanks in advance
Back to top
siavashhn



Joined: 29 Aug 2007
Posts: 15


Post10 Jun 2008 18:41   siemens - C7 - OP

I think my ESC button is damaged , beacuse when i press it, no bit in System-key DBW is changed.
Back to top
fakhur2000



Joined: 13 Jun 2008
Posts: 2


Post17 Jun 2008 6:34   Re: siemens - C7 - OP

i need help ,
i want to connect plc log with a load cell to its analog mode. the load cell is giving the voltage in mili volts. what should i do ?
thanks in advance
Back to top
siavashhn



Joined: 29 Aug 2007
Posts: 15


Post19 Jun 2008 17:27   siemens - C7 - OP

First of all what is your PLC brand and what do you mean by "plc log " ?
Back to top
FvM



Joined: 22 Jan 2008
Posts: 2632
Helped: 431
Location: Bochum, Germany


Post19 Jun 2008 18:34   siemens - C7 - OP

C7-634 has high volatage (10 V) analog input only and isn't suited for direct connection of a load cell.
Back to top
siavashhn



Joined: 29 Aug 2007
Posts: 15


Post21 Jun 2008 12:13   siemens - C7 - OP

of course there is some module to amplify and linearize the mv of your Loadcell to 0-10V or maybe 4-20mA.just find the module and buy it.For Example for a pt100 I bought a transducer which did all the zero and spaning things.... Good luck

P.S: You should be abale to find schematics for this transducer all over the web. just take a look
Back to top
venix



Joined: 20 Mar 2008
Posts: 43
Helped: 6


Post01 Jul 2008 19:11   Re: siemens - C7 - OP

Hi!
Right+Down+Esc= Hold and switchON = Delete Configuration & Set Password Default (100)
This will put C7 in transfer mode,but you must see if you want to delete configuration.

Best regards!
Venix

Added after 8 minutes:

Or you can try ESC+UP (during startup) for direct serial connection.

Best regards !
Venix