Post03 Jun 2008 11:52   ORCAD PROBLEM

dear friends,

if any one who is master in orcad can suggest me the way...

i need to change the diameter of the holes those are in peds. as my componats leads are of 1mm. dia.

how can i do that after i finished routing the pcb. or i can unroute the board if needed.
but suggest me the way plz.

thanks..
rony
Back to top
Raju_epigon



Joined: 13 Feb 2008
Posts: 66
Helped: 4


Post10 Jun 2008 9:23   Re: ORCAD PROBLEM

Hai,


you are using, which s/w for layout, is it layout?
confirm this one, then i will tell you.


Thanks,
R Raju
Back to top
Batke



Joined: 12 Nov 2001
Posts: 62
Location: PCB_LAND


Post10 Jun 2008 16:02   Re: ORCAD PROBLEM

ronydc wrote:
dear friends,

if any one who is master in orcad can suggest me the way...

i need to change the diameter of the holes those are in peds. as my componats leads are of 1mm. dia.

how can i do that after i finished routing the pcb. or i can unroute the board if needed.
but suggest me the way plz.

thanks..
rony


click pin tool, click on the pad you change, click spreadsheet/padstacks.

padstack is highlited, change drildwg/drill to desired value.
Back to top
ronydc



Joined: 17 Nov 2005
Posts: 77


Post20 Jun 2008 19:21   ORCAD PROBLEM

yes thts true. thanks, but can u suggest me .. wht value i need to take for gentral componants ( 0.5 mm dril) and for 1N5402 diode..( 1 mm drill) .?

thanks in advance friend...
Back to top
Batke



Joined: 12 Nov 2001
Posts: 62
Location: PCB_LAND


Post20 Jun 2008 22:41   Re: ORCAD PROBLEM

for this (1N5402) diode, drill 60 mils (1.5mm).

Code:
http://www.fairchildsemi.com/products/discrete/pdf/do201_dim.pdf


For other components see datasheets for them.
Back to top
Anonymous_Ricky



Joined: 26 Dec 2006
Posts: 127
Helped: 7


Post21 Jun 2008 7:07   ORCAD PROBLEM

Hi,

you yourself are mentioning that drill is 0.5mm and 1 mm so just add 0.7 mm to drill to get the actual pad size.
and in case you have pin diameter than add 0.3mm to get the drill and then 0.7mm to get pad size.

Regards,