12 Feb 2008 12:42 ICD 2 clone debugging |
|
|
|
|
I m using ICD2 Lotha's clone
Its working with PIC16F877A only at 4MHz
Cannot even connect when I use 20MHz
Is it a limitation of ICD or 16F877A?
How can I debug at 20MHz
the speed is critaical to me
Please help me
|
|
| Back to top |
|
 |
nimarc
Joined: 28 Jan 2007 Posts: 12
|
12 Feb 2008 13:16 ICD 2 clone debugging |
|
|
|
|
| Can U upload schematic and bootloader information so that I can check.
|
|
| Back to top |
|
 |
Google AdSense

|
12 Feb 2008 13:16 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
dewinda
Joined: 18 Jan 2008 Posts: 3
|
12 Feb 2008 13:45 ICD 2 clone debugging |
|
|
|
|
Im using stotz ICD as in his site
http://www.stolz.de.be/
16F877A on a bread board for testing
|
|
| Back to top |
|
 |
blueroomelectronics
Joined: 17 Sep 2006 Posts: 1681 Helped: 99 Location: Toronto, Canada
|
12 Feb 2008 14:56 ICD 2 clone debugging |
|
|
|
|
Sounds like you're not setting your CONFIG fuses right on your target PIC. Set to HS not XT.
PS Solderless Breadboards can be a problem at high frequencies.
|
|