I have a 70 Mhz VHF generator having maximum power rating of 1.5KW. The generator is connected to the matching box with a coaxial cable. The matching box is connected directly to the plasma chamber.
The question that I had was what should be the length of the cable from the generator to the matching box so that the line acts as a 50 ohm line. Sould it be λ/4 (quarter wavelength) , λ/2 (half) or λ.
|
|
| Back to top |
|
 |
VSMVDD
Joined: 12 Jun 2005 Posts: 558 Helped: 55
|
01 Oct 2007 22:04 Re: Coaxial Cable length for impedance match |
|
|
|
|
multiples of a quarterwave but not a full wave long
Added after 51 seconds:
multiples of a quarterwave but not a full wave long
so 1/4wave / velocity factor of the cable this is about 0.96 for 50ohm rg59u
cable quality is shit
i use 2X swr meter and a dummy load one at tx end other at dummy load
to trim for 1:1 both ends cut about 1/2 " off at a time
Last edited by VSMVDD on 01 Oct 2007 22:08; edited 1 time in total |
|
| Back to top |
|
 |
abhishek_rathod50
Joined: 05 May 2007 Posts: 9
|
01 Oct 2007 22:06 Coaxial Cable length for impedance match |
|
|
|
|
For 70MHz, RG393 (VF 0.694):
1/4 wavelength = 246/70 MHz = 3.514 feet long (electrical) x 0.694 VF = 2.43
1/4 wavelength is 2.43' or 29.26" so an odd
multiple is 3 x 29.26" or 87.8" length. Does this sound good?
|
|
| Back to top |
|
 |
VSWR
Joined: 07 Feb 2002 Posts: 767 Helped: 72
|
01 Oct 2007 22:13 Re: Coaxial Cable length for impedance match |
|
|
|
|
You have to give more details:
- what is the output impedance of the generator? 50 ohm?
- what is the input impedance of the matching box? 50 ohm?
|
|
| Back to top |
|
 |
abhishek_rathod50
Joined: 05 May 2007 Posts: 9
|
01 Oct 2007 22:16 Coaxial Cable length for impedance match |
|
|
|
|
| The output impedance of the generator is 50 ohm. Also I am using a 7/16 connector at the input of the matching box which is also a 50 ohm.
|
|
| Back to top |
|
 |
VSWR
Joined: 07 Feb 2002 Posts: 767 Helped: 72
|
01 Oct 2007 22:48 Re: Coaxial Cable length for impedance match |
|
|
|
|
| In that case you can use any length of the coaxial cable between the generator and the matching box. But be careful with the loss. As an example it is about 0.5 dB/10 m length at 70 MHz for RG-213/U coaxial cable.
|
|
| Back to top |
|
 |
sergio mariotti
Joined: 22 Dec 2003 Posts: 467 Helped: 42 Location: Italy
|
03 Oct 2007 23:33 Re: Coaxial Cable length for impedance match |
|
|
|
|
in my opinion the answer of VSMVDD is not correct.
It's well known that a λ/2 or λ long coax line take no changes on the impedance, even regardeless its Zo.
As opposite, λ/4 acts the strongest Z transformation.
for N λ/2 (N=1,2,3..) Zin = Zload regardeless for Zo
for N λ/4 (N=1,3,5..) Zin = ZoČ/Zload
Since the your power is very high, you should connect very well the brian before connect the cables
|
|
| Back to top |
|
 |
Google AdSense

|
03 Oct 2007 23:33 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
biff44
Joined: 24 Dec 2004 Posts: 1835 Helped: 244 Location: New England, USA
|
05 Oct 2007 11:53 Coaxial Cable length for impedance match |
|
|
|
|
| Man, what are you guys talking about? VSWR has the answer. You can put any length of characteristic impedance 50 ohm cable between your 50 ohm output generator and the matching box (assuming the matching box is actually working!).
|
|
| Back to top |
|
 |
FANT
Joined: 27 Feb 2002 Posts: 367 Helped: 12 Location: Italy
|
05 Oct 2007 12:37 Re: Coaxial Cable length for impedance match |
|
|
|
|
If both impedences are 50 Ohm any lenght of cable is OK,you have to take care only about the maximum power permitted on the cable. ( I suggest RG214 ).
If the impedance is different any lambda/2 or multiples will transfer the impedance of the generator to the load, any impedance of the cable used.
Mandi
|
|