Post05 Mar 2007 10:35   metal width

hi guys
how can i determine the power supply rail width according to the power consemption of the ckt
so guys pis tell me
ragards
analaout
Back to top
gafsos



Joined: 01 Feb 2006
Posts: 148
Helped: 11
Location: Africa


Post05 Mar 2007 13:46   Re: metal width

Normally DRM (design Rule MAnual) for the techno that u use, provide the maximum allowed Idc, Irms and Ipeak for each of the metal wiring levelsat junction temperatures of X°C.

See ur DRM

gafsos
Back to top
gingerjiang



Joined: 01 Mar 2006
Posts: 212
Helped: 11


Post05 Mar 2007 13:54   Re: metal width

enlarge the metal width as possible to reduce the voltage drop along the power supply rail
Back to top
xreaver



Joined: 27 Dec 2005
Posts: 25
Helped: 4


Post05 Mar 2007 14:33   Re: metal width

well you need to do Electromigration analysis on the metal line for
calculating the required metal width that can withstand the current to pass through it.
You can calculate Irms, Ipeak and Idc and put it in the formulas mentioned in
the DRM. you will exactly know how much metal width you need to maintain.

Added after 37 minutes:

Actually as you are only concerned about Power lines...VDD and VSS, you can calculate the Idc current . You can calculate the DC current by putting current sources for all the devices and find the current consumed by each circuit and then multiplied by voltage , you get the power consumption in your block. You can also calculate the average current by the CVF formula (capacitance*Voltage*frequency). Then use DRM to find out the metal width required..
Please do IR drop analysis too if your design block is power consuming. That will make sure whether your design block is getting good power supply all throughout..
Back to top
analayout



Joined: 20 Feb 2007
Posts: 94
Helped: 7


Post05 Mar 2007 15:18   metal width

the informations posted above r very usefull to me
thank u very much to all of u for your valuable suggessions
thanks
regards
analayout
Back to top
hung_wai_ming@hotmail.com



Joined: 05 Jan 2004
Posts: 364
Helped: 39


Post05 Mar 2007 17:01   metal width

Procedural flow for Electromigration analysis
(1) Do some analysis on your current consumption of the circuit, either by transient simulation or static IR drop analysis. however, be careful the IR drop is static meaning all devices are ON, so the analysis is over-exaggerated or run dynamic IR drop anaylsis
(2) Check with the PDK, most of the time, some figure of merit is around 0.7-0.8mA / um width of metal
(3) Do simple calculation for the required width
(4) Beware of peak current which can be a problem if you only do static calculation. Make sure your peak current won't happen so often and put de-couple cap enough on chip and off-chip to reduce the dynamic EM effect. Otherwise, your metal wire will still be melt out
(5) Finally, always a rule of thumb, everything over-design by 20-30%, by doubling the metal usage, put as many as vias as possible, no sharp 90 degree angles high current carrying metal, do metal slotting.
(6) Re-arrange the whole chip so that the thermal distribution is even
Back to top
penchal_gv



Joined: 04 Feb 2006
Posts: 20
Helped: 1


Post13 Apr 2007 11:49   Re: metal width

Hi,
As our friends said, first we have to check how much current (dc,rms,avg) will carry for 1um metal width. According to current requirement we have to calculate metal width.
Metal width=required current/current carrying for 1um metal width.
Apart from this metal width also calculated w.r.t voltage drop(resistance require).
metal width = required resistance/resistance per square (metal).
Back to top
siva497



Joined: 16 Apr 2007
Posts: 4
Helped: 1


Post16 Apr 2007 8:12   Re: metal width

preferably use max width for power...this will reduce ur IR drop values...
Back to top
pico



Joined: 30 Sep 2001
Posts: 261
Helped: 6


Post16 Apr 2007 8:45   metal width

http://www.ultracad.com/using_ipc_temp_charts.pdf

http://energy.ece.uiuc.edu/Balog/images/PCB%20Basics.pdf#search=%22robert%20s.balog%20pcb%22
Back to top
strennor



Joined: 09 Dec 2003
Posts: 62
Helped: 12


Post16 Apr 2007 9:18   metal width

calculate metal width by Metal Current Density.

know your current first, then times the density you get the metal width you need