29 Oct 2006 1:18 VCO phase noise |
|
|
|
|
For a VCO I measured in lab -30dBradČ/Hz of phase noise. Most of the examples I've seen express the phase noise in units of dBc/Hz, which I understand is the ratio of noise with respect of the carrier at a frequency offset.
What does radČ/Hz mean ??
regards !
|
|
| Back to top |
|
 |
Google AdSense

|
29 Oct 2006 1:18 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
RFDave
Joined: 18 Feb 2004 Posts: 346 Helped: 45 Location: NE USA
|
30 Oct 2006 14:02 Re: VCO phase noise |
|
|
|
|
Sounds like you measured integrated jitter instead. That's an unusual unit, what did you use to measure it?
Dave
|
|
| Back to top |
|
 |
STOIKOV
Joined: 18 Nov 2005 Posts: 295 Helped: 6
|
30 Oct 2006 18:06 Re: VCO phase noise |
|
|
|
|
| I used a vector signal analyzer Agilent 89410A. Want to measure the phase noise but the units radČ/Hz confuse me. Someone has used a similar instrument to obtain phase noise in dBc/Hz units ??
|
|
| Back to top |
|
 |
biff44
Joined: 24 Dec 2004 Posts: 1835 Helped: 244 Location: New England, USA
|
30 Oct 2006 20:14 Re: VCO phase noise |
|
|
|
|
www.minicircuits.com/appnote/vco15-6.pdf
http://surf.syr.edu/projects/vco/Phase_Noise.htm
|
|
| Back to top |
|
 |
RFDave
Joined: 18 Feb 2004 Posts: 346 Helped: 45 Location: NE USA
|
31 Oct 2006 0:27 Re: VCO phase noise |
|
|
|
|
Play around with the marker menu. That is where Agilent likes to hide those sorts of things.
Dave
|
|