12 May 2006 16:42 the boundary condition of microstrip line in CST? |
|
|
|
|
hi,friends
can someone tell me how to deal the boundary condition of a regular
microstrip line in CST?
best regards!
|
|
| Back to top |
|
 |
vtrs
Joined: 22 Mar 2006 Posts: 25 Helped: 5
|
14 May 2006 23:39 Re: the boundary condition of microstrip line in CST? |
|
|
|
|
You have first to add some air above the microstrip line with the "backround
material" tool and then set the boundary conditions to electric. It would be
better not to put symmetry planes because you have a quasi-TEM wave, else you may take incorrect results..Good luck!
|
|
| Back to top |
|
 |
gw_uestc
Joined: 11 May 2006 Posts: 26
|
15 May 2006 15:13 the boundary condition of microstrip line in CST? |
|
|
|
|
vtrs,thanks for your help!
As i know,the default background material in cst is just air,then whether i need add another air layer?
|
|
| Back to top |
|
 |
dch316
Joined: 09 Jun 2005 Posts: 49 Helped: 11 Location: Spain
|
16 May 2006 6:27 Re: the boundary condition of microstrip line in CST? |
|
|
|
|
hi,
yes you do need to put air because otherwise your PEC boundary above the microstrip line would be in touch with it, shortcircuiting it. I am not sure but probably CST would give an error message, or at least a warning message.
regards
|
|
| Back to top |
|
 |
Google AdSense

|
16 May 2006 6:27 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
Pushhead
Joined: 19 Jan 2005 Posts: 195 Helped: 8
|
16 May 2006 8:48 Re: the boundary condition of microstrip line in CST? |
|
|
|
|
I agree with the replies, and would just like to add something:
You can follow the CST examples and implement their setup in your model (look for "radial stub microstrip").
Good luck,
P.
|
|
| Back to top |
|
 |
vtrs
Joined: 22 Mar 2006 Posts: 25 Helped: 5
|
16 May 2006 13:04 Re: the boundary condition of microstrip line in CST? |
|
|
|
|
Dch316 is right,CST will not probably give an error message, but if you do not
put air above te microstrip line your structure will automatically become a planar waveguide..You must do the same thing if your ground plane is interrupted (i.e holes etched in ground,EBG stucture).In that case you must also be carefull while setting the waneguide ports
|
|
| Back to top |
|
 |