| Author |
Message |
EXPRESSTOM
Joined: 20 Aug 2008 Posts: 4 Location: York
|
20 Aug 2008 17:05 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Question ?
Sorry, I am new to this forum.
But why don't you just keep using the CY7C64613
There is still plenty of stock around
Thanks
Tom
|
|
| Back to top |
|
 |
MPi
Joined: 10 Jun 2006 Posts: 21 Location: Hungary
|
20 Aug 2008 18:27 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| EXPRESSTOM wrote: |
Sorry, I am new to this forum.
But why don't you just keep using the CY7C64613 |
Read the first remarks of the topic, and look at the inside of an original new ICD2.
|
|
| Back to top |
|
 |
El_gocho
Joined: 17 Sep 2008 Posts: 2
|
17 Sep 2008 21:01 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Hola a todos!
¿Alguién sabe cual de las versiones del clon funciona para dispositivos PIC24(3.3V)?
Hello everyone!
Does Anyone know which of the versions of the clone works for PIC24 devices (3.3V)?
|
|
| Back to top |
|
 |
AlexAlexwww
Joined: 23 Apr 2008 Posts: 1
|
18 Sep 2008 19:17 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
I have made ICD2 clone REV 2 .
I put on the 16f877a and the 18f4550 the bootloader on the zip folder.
But it doesn't work.
The first problem is the white led (USB), When i touch the pin 1 the led will turn on and off (it doesn't turn on when i plug on the USB).
The second is that when I plug it to the USB nothing appear on the screen (the PC doesn't recognize the programmer).
What I have to do?
This is the screen displayed on MPLAB 7.60 when i tryed to connect
Connecting to MPLAB ICD 2
ICD0019: Communications: Failed to open port: (Windows::GetLastError() = 0x2, 'Impossibile trovare il file specificato.
')
ICD0021: Unable to connect with MPLAB ICD 2
MPLAB ICD 2 Ready
I hope I can help me.
Thanks ALex
Added after 4 minutes:
I missed to specify that is my only programmer.
The IC's were programmed by my friend.
|
|
| Back to top |
|
 |
SG61-addict
Joined: 08 Mar 2008 Posts: 8
|
01 Oct 2008 20:53 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
I tried to read the forum...
| Quote: |
Hi,
I just wanted to say thanks to all of you guys who helped make the ICD2clone. It works !!
I've build "potyo2 (09/18/2006)" from http://icd2clone.com/wiki/Main_Page.
At first using MPLAB 8.10 I had problems connecting to the ICD2.
| Code: |
ICD0021: Unable to connect with MPLAB ICD 2
MPLAB ICD 2 Ready. |
I had to go down to MPLAB 7.40 before my ICD2 was recognized and a firmware downloaded.
Now it works with all versions of mplab (7.40 and up). |
I have the same problem ! But your solution don't work on my board. I installed MPLAB7.40 on an other computer, I get first :
| Code: |
ICD0021: Unable to connect with MPLAB ICD 2
MPLAB ICD 2 Ready |
And after download OS :
| Code: |
Downloading Operating System
ICD0255: Download OS failed.
...Download Operating System Failed
ICD0029: Connected tool is not an MPLAB ICD 2: Product ID = 0x0 (MPLAB ICD (1))
ICD0082: Failed MPLAB ICD 2 operation
ICD0082: Failed MPLAB ICD 2 operation
ICD0082: Failed MPLAB ICD 2 operation
ICD0082: Failed MPLAB ICD 2 operation
MPLAB ICD 2 Ready |
I'm going to work on other projects. I have already my own offical ICD2, I just want to built some clones for a friend and an students association, but, in terms of $,
Official ICD2 price << The money I could win by working instead of debug clone :
More than 10 hours for the same result :
| Code: |
ICD0021: Unable to connect with MPLAB ICD 2
MPLAB ICD 2 Ready |
No motivation to continue...
I hope someone could help me. Nobody tried potyo2 on MPLAB 8.10 ???
|
|
| Back to top |
|
 |
blueroomelectronics
Joined: 17 Sep 2006 Posts: 1681 Helped: 99 Location: Toronto, Canada
|
01 Oct 2008 22:16 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| Build a PICkit2 clone like my Junebug. Much more reliable than a ICD2 clone. Self powered too.
|
|
| Back to top |
|
 |
potyo
Joined: 16 Apr 2006 Posts: 181 Helped: 10 Location: Ada, Vajdaság
|
02 Oct 2008 12:13 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| SG61-addict wrote: |
| Nobody tried potyo2 on MPLAB 8.10 ??? |
I'm working with it under MPLAB 8.10. It must work with all MPLAB versions, because it uses the same firmware as official ICD2.
| SG61-addict wrote: |
| ICD0029: Connected tool is not an MPLAB ICD 2: Product ID = 0x0 (MPLAB ICD (1)) |
There is a great chance that you have a short circuit or break on the wires between 16F877 and 18F4550.
Last edited by potyo on 02 Oct 2008 12:18; edited 4 times in total |
|
| Back to top |
|
 |
SG61-addict
Joined: 08 Mar 2008 Posts: 8
|
02 Oct 2008 12:13 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| Does PIC kit 2 can program 3.3V dsPIC33 ?
|
|
| Back to top |
|
 |
potyo
Joined: 16 Apr 2006 Posts: 181 Helped: 10 Location: Ada, Vajdaság
|
02 Oct 2008 12:16 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| SG61-addict wrote: |
| Does PIC kit 2 can program 3.3V dsPIC33 ? |
It is a large problem to check the list of supported chips on Microchip's site?
|
|
| Back to top |
|
 |
gsila
Joined: 15 Mar 2007 Posts: 1
|
05 Oct 2008 9:45 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Who can check my PCB if there are any errors
|
|
| Back to top |
|
 |
medvonok
Joined: 15 Jun 2006 Posts: 14 Location: Romania
|
13 Oct 2008 16:19 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
I don`t now witch variant is good (for MC34063A):
Cin = 47uF or 100uF
Cout = 100uf or 220uF.
What is total power for ICD2 = more than 100mA / 5V ?
Thank you.
|
|
| Back to top |
|
 |
elmasvital
Joined: 13 Jun 2007 Posts: 6
|
15 Oct 2008 8:42 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| medvonok wrote: |
I don`t now witch variant is good (for MC34063A):
Cin = 47uF or 100uF
Cout = 100uf or 220uF.
What is total power for ICD2 = more than 100mA / 5V ?
Thank you. |
No, MC34063A is only to generate 13v to mclr.
|
|
| Back to top |
|
 |
Lucidan
Joined: 04 Oct 2008 Posts: 5
|
26 Nov 2008 19:02 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| Shouldn't someone (admin) create a dedicated section for PIC programmers? Browsing the 'microcontroller'-section for programmer stuff really is becoming a nuisance.
|
|
| Back to top |
|
 |
hartfelder
Joined: 26 Nov 2008 Posts: 5
|
27 Nov 2008 13:03 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Does anyone know why this ICD2 have only one PIC? and it's USB...
check..
http://www.microgenios.com.br/news/index.php?option=com_content&task=view&id=101&Itemid=152
I want to build a ICD2, but this one is very interesting, and it's cheap.
|
|
| Back to top |
|
 |
nooknikz
Joined: 22 Apr 2002 Posts: 404 Helped: 22 Location: thailand
|
27 Nov 2008 15:04 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| hartfelder wrote: |
Does anyone know why this ICD2 have only one PIC? and it's USB...
check..
http://www.microgenios.com.br/news/index.php?option=com_content&task=view&id=101&Itemid=152
I want to build a ICD2, but this one is very interesting, and it's cheap. |
I think it is PICKIT2 Board.
---------------------------------
Micro4you Store
|
|
| Back to top |
|
 |
MPi
Joined: 10 Jun 2006 Posts: 21 Location: Hungary
|
08 Dec 2008 19:54 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| nooknikz wrote: |
| hartfelder wrote: |
Does anyone know why this ICD2 have only one PIC? and it's USB...
check..
http://www.microgenios.com.br/news/index.php?option=com_content&task=view&id=101&Itemid=152
I want to build a ICD2, but this one is very interesting, and it's cheap. |
I think it is PICKIT2 Board. |
Yes, it's a PICKit2 clone with a PIC18F2550.
|
|
| Back to top |
|
 |
hartfelder
Joined: 26 Nov 2008 Posts: 5
|
12 Dec 2008 3:26 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Hi,
I made a ICD2 PiCS Rev. B, but I'm having some problems...
The first time that I connected my ICD2 on my computer, the firmware was installed correctly, but in the MPLAB he doesn't connect well... see,
Auto-connect not enabled - Not connecting (Try enabling auto-connect on the ICD2 settings pages.)
Connecting to MPLAB ICD 2
...Connected
ICD0082: Failed MPLAB ICD 2 operation
Connecting to MPLAB ICD 2
...Connected
ICD0082: Failed MPLAB ICD 2 operation
ICD0286: Unable to communicate with ICD
MPLAB ICD 2 ready for next operation
What can be? I've checked twice my PCB, and it appers to be ok, all connection are right.
I think it is the firmware, I'm using the firmware that comes with the PiCS Rev.B, using a 10K resistor in MCRL in 18F4550. I need help guys! thanks....
|
|
| Back to top |
|
 |
lucafus
Joined: 28 Apr 2006 Posts: 11
|
12 Dec 2008 13:06 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Hi Hartfelder!
Did you try manually downloading the ICD2 operating system? (In Debugger window -> Download ICD2 Operating System).
Good luck.
Luca.
|
|
| Back to top |
|
 |
hartfelder
Joined: 26 Nov 2008 Posts: 5
|
12 Dec 2008 14:12 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Hi lucafus,
I tried, but he start the downloading and never stops.
I'm using the MPLAB 8.14...
Added after 24 minutes:
Hey, I tried now and connected!
I need now program some PIC to verify if it's working!
thnks!
|
|
| Back to top |
|
 |
hartfelder
Joined: 26 Nov 2008 Posts: 5
|
15 Dec 2008 19:08 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Yes, my ICD2 PiCS Rev. B works perfectly! I've should only put a 10k resistor in the 4550 in his MCLR.
Someone here has the PCB where the PIC will be wrote? DIL SOCKET... thanks!
|
|
| Back to top |
|
 |
roddick
Joined: 20 Jun 2007 Posts: 2
|
16 Dec 2008 17:30 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Dear all,
first,sorry my english.
i build Potyo2-2006.12.07 icd2.
i can prgramming MCU
but,in debug mode,after programming 16f877(my target MCU)
step into,step over,animate all it's ok,no error.
but i press run bottom,then i see the ICD2 error and busy LED is blink
then,i press halt bottom,appear these information
Running Target
Halting Target
ICDWarn0054: MPLAB IDE has lost communications with the MPLAB ICD 2. Would you like to attempt to reconnect?
ICD0286: Unable to communicate with ICD
MPLAB ICD 2 Ready
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to MPLAB ICD 2
Target Device PIC16F877 found, revision = b8
...Reading ICD Product ID
Running ICD Self Test
...Passed
ICD0082: Failed MPLAB ICD 2 operation
...Halt Failed
MPLAB ICD 2 Ready
if i press step into, step over or animate buttom,then press reset bottom,
it's same the situation,icd2 will lost communications
what's wrong my icd2 ??
please help me,thanks.
Best Regards,
roddick.
|
|
| Back to top |
|
 |
roddick
Joined: 20 Jun 2007 Posts: 2
|
19 Dec 2008 15:06 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Dear all,
i have a mistake
now the problem is slove
i use 74LS126 and 74LS125,but the 4066 is cd4066,not 74HC4066
maybe TTL IC can't driver CMOS IC,cause this problem
now i use 74HC126 and 74HC125
the potyo version icd2,it can entrance debug mode
|
|
| Back to top |
|
 |
Computerman29
Joined: 23 Jul 2006 Posts: 135 Helped: 4 Location: Valparaiso, IN USA
|
21 Dec 2008 13:38 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
Greetings,
| Quote: |
| i use 74LS126 and 74LS125,but the 4066 is cd4066,not 74HC4066 |
74LS126/125 will not work. Use 74HC. Also, CD4066 is actually a better choice because 74HC4066 is switching Vpp (13v) which exceeds the maximum voltage rating. CD4066 has higher voltage rating (but it is slower and draws more current). I think the 74HC4066 will work fine though.
|
|
| Back to top |
|
 |
mistey
Joined: 28 Oct 2006 Posts: 9
|
02 Jan 2009 19:44 |
|
|
|
|
Hi all.
I made a RS232 ICD. I used PIC16F876.
Which firmware should i use?
thanks
Here is schematic:
|
|
| Back to top |
|
 |
Google AdSense

|
02 Jan 2009 19:44 Ads |
|
|
|
|
|
|
| Back to top |
|
 |
blueroomelectronics
Joined: 17 Sep 2006 Posts: 1681 Helped: 99 Location: Toronto, Canada
|
02 Jan 2009 22:36 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| Use the BLxxxxx.hex file that's part of your MPLAB install
|
|
| Back to top |
|
 |
mistey
Joined: 28 Oct 2006 Posts: 9
|
02 Jan 2009 22:47 Re: Project to replace CY7C64613 in the ICD2 |
|
|
|
|
I'm using MPLAB 8.10. Still BL010101?
I got massage in mplab:
Connecting to MPLAB ICD 2
ICD0021: Unable to connect with MPLAB ICD 2
MPLAB ICD 2 Ready
I check the pcb. seems good
How can i test it without connecting a target pic?
thanx
|
|
| Back to top |
|
 |
blueroomelectronics
Joined: 17 Sep 2006 Posts: 1681 Helped: 99 Location: Toronto, Canada
|
03 Jan 2009 1:17 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| You must be using a hardware (NOT USB) based serial port. How did you program the 16F876
|
|
| Back to top |
|
 |
mistey
Joined: 28 Oct 2006 Posts: 9
|
03 Jan 2009 1:22 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| yes. seri port based. jdm programmer. shuld i change configurations in icprog?
|
|
| Back to top |
|
 |
blueroomelectronics
Joined: 17 Sep 2006 Posts: 1681 Helped: 99 Location: Toronto, Canada
|
03 Jan 2009 1:25 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| The config fuses might be set wrong. WDT_OFF, HSOSC
|
|
| Back to top |
|
 |
mistey
Joined: 28 Oct 2006 Posts: 9
|
03 Jan 2009 1:31 Project to replace CY7C64613 in the ICD2 |
|
|
|
|
| thanx blueroomelectronics. when i load hex file. it aoutomaticly sets HS and WRT_ON, other OFF
|
|
| Back to top |
|
 |