electronics forum

Rules | Recent posts | topic RSS | Search | Register  | Log in

What happens when we connect two different gorunds?


Post new topic  Reply to topic    EDAboard.com Forum Index -> Analog Circuit Design -> What happens when we connect two different gorunds?
Author Message
seyyah



Joined: 07 Oct 2001
Posts: 578
Helped: 1


Post30 Mar 2005 9:37   

What happens when we connect two different gorunds?


My µcontroller was operating normally. There was only one supply at that moment. Than i plugged out the power cables to connect two different supplys grounds. One of them is 5VDC and the other is 33VDC. I made the connections of the grounds with the supplies are offline. But the main capacitors of the supplies were charged i think. After this µcontroller didn't work. I think it burnt. What may cause this? A negative transient? What should we do to prevent this kind of damages?
Back to top
Google
AdSense
Google Adsense




Post30 Mar 2005 9:37   

Ads




Back to top
_i386sx25_



Joined: 02 Jun 2002
Posts: 60
Helped: 4


Post30 Mar 2005 18:19   

Re: What happens when we connect two different gorunds?


If both supply is not isolated , there could be ground current leakage. In that case there would be potential difference between both grounds which causes a current flow. That could destroy your circuit. Check the isolation and potential difference between two power supply.
Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> Analog Circuit Design -> What happens when we connect two different gorunds?
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
What happens when a thyristos fails? (3)
What happens to metals when melted? (2)
what happens when fpgs is overloaded??? (12)
What happens when not enough vias area drawn? (5)
What happens when the errors larger than t (RS FEC)? (3)
What happens when there is an incoming call (GPRS w/ SIM300) (3)
What happens if 12V bat is connect in parallel wif a 5V bat? (15)
What happen when connect the N-well and P-sub to the ground? (5)
what happens to be Vo if we remove feedback in opamp (4)
what happens to the return currents (1)


Abuse || Administrator || Moderators || Support us || sitemap
topic RSS