electronics forum

Rules | Recent posts | topic RSS | Search | Register  | Log in

DAQ interfacing, what is the best way to measure the data ?


Post new topic  Reply to topic    EDAboard.com Forum Index -> PC Programming and Interfacing -> DAQ interfacing, what is the best way to measure the data ?
Author Message
hamadeh



Joined: 10 Dec 2004
Posts: 98
Helped: 10
Location: Lebanon


Post08 Jan 2005 10:04   

DAQ interfacing, what is the best way to measure the data ?


Hi ,

I have a 16 bit DAQ connected to a PC using the USB port, NI LabVIEW driver for this DAQ is available, I want to connect a pressure transducer to this DAQ to measure some pressure value between the lips, what I want to ask is the following:
What is the best method to measure the pressure value from the transducer ? , is it to get the maximum obtained value from the DAQ or something else ?

Thanks in Advance.
Back to top
Google
AdSense
Google Adsense




Post08 Jan 2005 10:04   

Ads




Back to top
IanP



Joined: 05 Oct 2004
Posts: 6490
Helped: 1542
Location: West Coast


Post08 Jan 2005 10:57   

Re: DAQ interfacing, what is the best way to measure the dat


1. Resolution:
In your case you have 16bits what gives you 65536 steps.
2. Input ranges:
Again, in your cas you hav Nationa Instruments DAQ card, so it is quite possible that you will be able to select the following input ranges: 0V to 5V, -5V to +5V, 0V to 10V and -10V to +10V.
3. Pressure transducer: it is very common that they are of 4-20mA devices.
Now, you have to select termination resistor. Very common value will be 250Ω and that operates in the ronge of 1Vdc (at 4mA) to 5Vdc (at 20mA).

So normal selection of the possible input ranges will be 0V - 10V.
However, if instead of 250Ω you select 220Ω you can select 0V - 5V with resolution close to 67µ (5V/65536).
Also, be aware that the lowest voltage will not be 0V but 1V(at)250Ω or 0.88(at)220Ω.

For normal situation you will be more tyhan happy having pressure resolution of 0.1bar for a pressure transducer 0-100bar or even 0-10bar so you will drop some low bits from available 16.

The main criterion is always resolution you are happy with..
Back to top
Arabic versionBulgarian versionCatalan versionCzech versionDanish versionGerman versionGreek versionEnglish versionSpanish versionFinnish versionFrench versionHindi versionCroatian versionIndonesian versionItalian versionHebrew versionJapanese versionKorean versionLithuanian versionLatvian versionDutch versionNorwegian versionPolish versionPortuguese versionRomanian versionRussian versionSlovak versionSlovenian versionSerbian versionSwedish versionTagalog versionUkrainian versionVietnamese versionChinese version
Post new topic  Reply to topic    EDAboard.com Forum Index -> PC Programming and Interfacing -> DAQ interfacing, what is the best way to measure the data ?
Page 1 of 1 All times are GMT + 1 Hour
Similar topics:
What is the best way to measure main voltage with isolation (18)
What is the best way to go? (2)
what is the best way to learn (4)
What is the best way to master VHDL (4)
What is the best way to Sample an analog signal? (2)
What is the best way to detect motor stall. (3)
Coaxial Coupler: What is the best way to design? (4)
What is the best way to simulate IIP3 by Spectre? (2)
What is the best way to start analog IC design? (15)
What is the best way to learn microlontroller programming (1)


Abuse || Administrator || Moderators || Support us || sitemap
topic RSS